AIR CONDITIONER
4-unit multi-split type,
5-unit multi-split type
DESIGN & TECHNICAL MANUAL
INDOOR
AUXG07–22KVLA ARXG07–14KSLAP
ARXG18KSLAP
ARXG07–14KLLAP
ARXG18KLLAP
ARXG22KMLB
ARXH22KMTAP ASYG07–14KGTB ASYG07–14KGTE
ASYG07–14KGTF
ASYG18–24KMTB
ASYG18–24KMTE
ASYG07–14KMTB
ASYG07–14KMCC
ASYG07–14KMCE
ASYG07–14KMCF
OUTDOOR
ASYG07–14KETA
ASYG07–14KETE
ASYG07–14KETF
ASYG07–14KETA-B
ASYG07–14KETE-B
ASYG07–14KETF-B
ABYG18–22KRTA AGYG09–14KVCA AOYG30KBTA4
AOYG36KBTA5
DR_MU025EF_10
2023.09.20

Table of Contents

Other manuals for Fujitsu ASYG07KGTB

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG07KGTB and is the answer not in the manual?

Fujitsu ASYG07KGTB Specifications

General IconGeneral
BrandFujitsu
ModelASYG07KGTB
CategoryAir Conditioner
LanguageEnglish

Summary

Part 1. INDOOR UNIT

Model lineup

Presents an overview of the available indoor unit models, categorized by type.

Specifications

Provides detailed technical specifications for various indoor unit types.

Wireless LAN control

Details system requirements for wireless LAN control using mobile app.

Dimensions

Provides dimensional data for different indoor unit types.

Wiring diagrams

Illustrates the wiring diagrams for various indoor unit types.

Air velocity and temperature distributions

Presents air velocity and temperature distribution charts for indoor units.

Fan performance

Details the fan performance curves for different indoor unit types.

Airflow

Lists airflow rates (m³/h, l/s, CFM) for various indoor unit models.

Noise level curve

Presents noise level curves (dB) for various indoor unit types across frequencies.

Electrical characteristics

Details electrical specifications for indoor units, including power supply and wiring.

Safety devices

Lists safety devices and their operational parameters for indoor units.

External input and output

Explains how to connect external devices for input and output control.

Group connection

Details the system for connecting multiple indoor units for group control.

Remote controller

Overview of wireless and wired remote controller models and their functions.

Function settings

Describes various function settings available for indoor units, often via DIP switches or remote controllers.

Accessories

Lists available accessories for different indoor unit types.

Optional parts

Details optional parts such as controllers and grilles for indoor units.

Indoor unit installation precautions

Provides essential precautions for the safe and correct installation of indoor units.

Part 2. OUTDOOR UNIT (4 UNITS TYPE)

Specifications

Provides detailed specifications for the 4-unit outdoor type.

Dimensions

Presents the physical dimensions of the 4-unit outdoor type.

Installation space

Details the required installation space for the 4-unit outdoor type.

Refrigerant circuit

Illustrates the refrigerant circuit for the 4-unit outdoor type.

Wiring diagram

Shows the wiring diagram for the 4-unit outdoor type.

Capacity table

Provides capacity tables for various combinations of indoor units.

Capacity compensation rate for pipe length and height difference

Explains capacity compensation based on pipe length and height difference.

Additional charge calculation

Details the calculation method for additional refrigerant charge.

Airflow

Lists airflow rates (m³/h, l/s, CFM) for the outdoor unit.

Operation noise (sound pressure)

Presents noise level curves (dB) for the outdoor unit across frequencies.

Electrical characteristics

Details electrical specifications for the outdoor unit.

Safety devices

Lists safety devices and their operational parameters for the outdoor unit.

Function settings

Describes various function settings for the outdoor unit.

Check and test

Outlines procedures for checking and testing the outdoor unit.

Accessories

Lists available accessories for the outdoor unit.

Outdoor unit installation precautions

Provides essential precautions for the safe and correct installation of outdoor units.

Part 3. OUTDOOR UNIT (5 UNITS TYPE)

Specifications

Provides detailed specifications for the 5-unit outdoor type.

Dimensions

Presents the physical dimensions of the 5-unit outdoor type.

Installation space

Details the required installation space for the 5-unit outdoor type.

Refrigerant circuit

Illustrates the refrigerant circuit for the 5-unit outdoor type.

Wiring diagram

Shows the wiring diagram for the 5-unit outdoor type.

Capacity table

Provides capacity tables for various combinations of indoor units.

Capacity compensation rate for pipe length and height difference

Explains capacity compensation based on pipe length and height difference.

Additional charge calculation

Details the calculation method for additional refrigerant charge.

Airflow

Lists airflow rates (m³/h, l/s, CFM) for the outdoor unit.

Operation noise (sound pressure)

Presents noise level curves (dB) for the outdoor unit across frequencies.

Electrical characteristics

Details electrical specifications for the outdoor unit.

Safety devices

Lists safety devices and their operational parameters for the outdoor unit.

Function settings

Describes various function settings for the outdoor unit.

Check and test

Outlines procedures for checking and testing the outdoor unit.

Accessories

Lists available accessories for the outdoor unit.

Optional parts

Details optional parts like communication kits and filters.

Outdoor unit installation precautions

Provides essential precautions for the safe and correct installation of outdoor units.