Fujitsu ASYG07-14KETF / AOYG07-14KETA Wall Mounted Air Conditioner
This document provides a comprehensive design and technical manual for the Fujitsu ASYG07-14KETF series (indoor units) and AOYG07-14KETA series (outdoor units) wall-mounted inverter heat pump air conditioners, utilizing R32 refrigerant.
Function Description
The Fujitsu ASYG07-14KETF / AOYG07-14KETA series offers both cooling and heating functionalities, operating as an inverter heat pump system. Key operational modes and features include:
- Operation On/Off: Basic control to power the unit on or off.
- Operation Mode Setting: Allows selection of various modes such as cooling, heating, dry, and fan-only.
- Set Temperature Setting: Users can adjust the desired room temperature.
- Fan Speed Setting: Multiple fan speeds (High, Med, Low, Quiet) are available for comfort and noise control.
- Airflow Direction Setting: Includes louver position adjustment (up/down) and swing function for optimal air distribution.
- Timer Operations: Features Off timer, On timer, Sleep timer, On/off program timer, and a Weekly timer for scheduled operation.
- Additional Functions:
- POWERFUL operation setting: For rapid cooling or heating.
- ECONOMY operation setting: To optimize energy consumption.
- 10 °C HEAT operation setting: Maintains a minimum room temperature of 10°C to prevent freezing.
- Room temperature indication: Displays the current room temperature.
- Fan control for energy saving: Adjusts fan operation to save energy during cooling.
- Outdoor unit low noise operation setting: Reduces outdoor unit noise for quieter operation.
- Wireless LAN Control: Allows remote control via a mobile app ("AIRSTAGE Mobile") on iOS or Android devices, providing control over most functions from outside the home. This requires a compatible wireless router (IEEE802.11b/g/n, 2.4 GHz frequency band, supporting WEP, WPA (PSK), WPA2 Personal (PSK), WPS).
- External Input and Output: Provides interfaces for external control and status monitoring.
- External Input: "Operation/Stop" mode or "Forced stop" mode can be selected. Supports both dry contact and applied voltage input signals (DC 12V to 24V, 1mA to 15mA). Input signal types can be "Edge" (alternate type switch) or "Pulse" (momentary type switch, pulse width > 200 msec).
- External Output: Provides operation status, error status, and indoor unit fan operation status. Output voltage is DC 12V ±2V (High) or 0V (Low), with a permissible current of 50mA.
- Group Connection: Up to 16 indoor units can be operated simultaneously with a single remote controller. Automatic address setting simplifies installation.
- Function Settings: Various settings can be adjusted via the wireless remote controller to adapt to the installation environment, including:
- Filter sign: Sets intervals for filter cleaning reminders (Standard, Long, Short, or No indication).
- Room temperature control for indoor unit sensor: Allows correction of the room temperature sensor reading (e.g., -0.5°C to -4.0°C or +0.5°C to +4.0°C).
- Room temperature control for wired remote controller sensor: Similar temperature correction for wired remote controller sensors.
- Auto restart: Enables or disables automatic restart after a power interruption.
- Room temperature sensor switching (Aux.): Selects between indoor unit sensor, wired remote controller sensor, or both.
- Remote controller custom code: Allows changing the custom code for wireless remote controllers to prevent interference with other units.
- External input control: Configures the behavior of external input signals (Operation/Stop mode 1 or 2, Forced stop mode).
- Indoor unit fan control for energy saving for cooling: Controls fan rotation when the outdoor unit is stopped during cooling.
- Switching functions for external output terminal: Configures the output terminal for operation status, error status, or indoor unit fan operation status.
Important Technical Specifications
Indoor Units (ASYG07KETF, ASYG09KETF, ASYG12KETF, ASYG14KETF, and -B models):
- Power Supply: 230 V~, 50 Hz.
- Available Voltage Range: 198-264 V.
- Capacity (Rated):
- ASYG07KETF: Cooling 2.0 kW (6,800 Btu/h), Heating 2.5 kW (8,500 Btu/h)
- ASYG09KETF: Cooling 2.5 kW (8,500 Btu/h), Heating 2.8 kW (9,500 Btu/h)
- ASYG12KETF: Cooling 3.4 kW (11,600 Btu/h), Heating 4.0 kW (13,600 Btu/h)
- ASYG14KETF: Cooling 4.2 kW (14,300 Btu/h), Heating 5.4 kW (18,400 Btu/h)
- Energy Efficiency Class: Cooling A++, Heating A+.
- SEER (Cooling): 6.9 - 7.4 kWh/kWh.
- SCOP (Heating): 4.1 - 4.4 kWh/kWh.
- Dimensions (H x W x D): 295 x 950 x 230 mm (for all models).
- Net Weight: 11.0 kg (ASYG07-12KETF), 11.5 kg (ASYG14KETF).
- Refrigerant: R32.
- Connection Pipe: Liquid Ø6.35 (Ø1/4) mm, Gas Ø9.52 (Ø3/8) mm (Flare type).
- Drain Hose Tip Diameter: Ø13.8 (I.D.), Ø15 to Ø16.8 (O.D.).
- Operation Range: Cooling 18 to 32 °C, Heating 16 to 30 °C.
- Fan Type: Crossflow fan x 1.
- Fan Motor Output: 22 W (ASYG07KETF), 24 W (ASYG09KETF), 27 W (ASYG12KETF), 30 W (ASYG14KETF).
- Sound Pressure Level (Cooling/Heating, HIGH): 38-44 dB(A) depending on model.
- Safety Devices: Current fuse (250V, 3.15A), Thermistor protection (More than 85°C fan speed down, 85°C or less fan speed recover), Power IC thermal shutdown (125±25°C fan motor stop, 110+25-20°C fan motor restart for ASYG14KETF).
Outdoor Units (AOYG07KETA, AOYG09KETA, AOYG12KETA, AOYG14KETA):
- Power Supply: 230 V~, 50 Hz.
- Available Voltage Range: 198-264 V.
- Starting Current: 3.0 A (AOYG07KETA), 3.4 A (AOYG09KETA), 5.1 A (AOYG12KETA), 6.8 A (AOYG14KETA).
- Max Operating Current: 9.0 A.
- Circuit Breaker Current: 15 A.
- Dimensions (H x W x D):
- AOYG07-12KETA: 541 x 663 x 290 mm (Net), 602 x 804 x 375 mm (Gross)
- AOYG14KETA: 542 x 799 x 290 mm (Net), 602 x 940 x 375 mm (Gross)
- Net Weight: 23 kg (AOYG07KETA), 25 kg (AOYG09KETA), 29 kg (AOYG12KETA), 31 kg (AOYG14KETA).
- Refrigerant: R32 (Global warming potential 675).
- Factory Charge Amount: 600 g (AOYG07/09KETA), 700 g (AOYG12KETA), 850 g (AOYG14KETA).
- Additional Charge: 20 g/m for pipe lengths exceeding 15 m.
- Refrigerant Oil: RB74AF (240 cm³) or RB68A (340 cm³).
- Connection Pipe: Liquid Ø6.35 (Ø1/4) mm, Gas Ø9.52 (Ø3/8) mm (Flare type).
- Max. Pipe Length: 15 m (pre-charged), 20 m (max.).
- Max. Height Difference: 15 m.
- Operation Range: Cooling -10 to 46 °C, Heating -15 to 24 °C.
- Fan Type: Propeller fan x 1.
- Fan Motor Output: 23 W (AOYG07-12KETA), 30 W (AOYG14KETA).
- Sound Pressure Level (Cooling/Heating): 46-50 dB(A) depending on model.
- Safety Devices: Current fuse (250V, 20A or 5A), Terminal protection program (85-122°C fan motor stop, 77-114°C fan motor restart), Terminal protection program (discharge temp.) (110°C compressor stop, after 7 minutes compressor restart).
Usage Features
- User-Friendly Remote Control: The wireless remote controller features a clear LCD display with indicators for mode, temperature, fan speed, swing, low noise mode, and clock/timer. It includes dedicated buttons for 10°C HEAT, TEMP, POWERFUL, ECONOMY, OUTDOOR UNIT LOW NOISE, SWING, SET, WEEKLY, ON/OFF, SLEEP, RESET, and TEST RUN.
- Mobile App Integration: "AIRSTAGE Mobile" app provides convenient remote control and monitoring capabilities, enhancing user experience and flexibility.
- Flexible Installation: Designed for wall-mounted installation, with clear guidelines for required installation space to ensure optimal performance and safety. Multiple outdoor units can be installed in various configurations (single parallel, multiple parallel, with obstructions).
- Customizable Settings: Extensive function settings allow installers to tailor the unit's operation to specific environmental conditions and user preferences, including temperature sensor correction, auto restart, and energy-saving modes.
- Group Control: Simplifies management of multiple indoor units in a single system, ideal for larger spaces or multiple rooms.
- Optional Controllers: A range of optional wired remote controllers (UTY-RNRYZ*, UTY-RLRY, UTY-RCRYZ1, UTY-RSRY, UTY-RHRY) offer different interfaces and functionalities, including finger touch operation, backlit LCDs, and compact designs.
- External Connectivity: Support for external input/output allows integration with building management systems or other control devices. Optional communication kits (UTY-XWZX, UTY-XWZXZ5, UTY-XCSXZ2, UTY-TWRXZ2) and converters (Modbus, KNX, Network) expand connectivity options.
Maintenance Features
- Filter Sign: The filter sign function on the remote controller reminds users when to clean the air filters, ensuring consistent air quality and unit efficiency.
- Error Status Output: The external output terminal can be configured to provide an error status signal, facilitating quick identification of malfunctions.
- Safety Devices: Built-in safety devices, including current fuses and thermistor protection for both indoor and outdoor units, protect the system from electrical overloads and overheating, contributing to reliability and longevity.
- Troubleshooting Information: The manual provides detailed wiring diagrams and function setting explanations to assist technicians in installation, configuration, and troubleshooting.
- Technical Specifications: Comprehensive technical data, including airflow rates, sound levels, and refrigerant circuit diagrams, are provided to support maintenance and repair activities.