INDOOR UNIT
OUTDOOR UNIT
CAPACITY
CAPACITY
POWER SOURCE
RUNNING CURRENT
RUNNING CURRENT
MAXIMUM CURRENT
MAXIMUM CURRENT
POWER CONSUMPTION
POWER CONSUMPTION
EER
COP
Heating Cooling
MOISTURE REMOVAL
ASYG14KGTA
AOYG14KGCA
ASYG12KGTA
AOYG12KGCA
4.20 kW
5.40 kW
3.40 kW
4.00 kW
230 V 50 Hz Single phase
5.3 A
6.4 A
6.5 A 9.0 A
9.0 A 10.5 A
1.175 kW
1.350 kW
3.57 kW/kW
4.00 kW/kW
2.1 L/h
4.3 A
4.8 A
0.805 kW
0.91 kW
4.22 kW/kW
4.40 kW/kW
1.8 L/h
700 m
3
/h
560 m
3
/h
430 m
3
/h
250 m
3
/h
770 m
3
/h
640 m
3
/h
520 m
3
/h
310 m
3
/h
1,680 m
3
/h
1,580 m
3
/h
770 m
3
/h
600 m
3
/h
450 m
3
/h
280 m
3
/h
800 m
3
/h
660 m
3
/h
520 m
3
/h
340 m
3
/h
1,680 m
3
/h
1,580 m
3
/h
FAN MOTOR AND FAN REVOLUTION
OUTDOOR UNIT’S Discrimination
MFE-W25VA2F
INDOOR UNIT’S Discrimination
MFD-U50XA3F
High
INDOOR UNIT
Cooling
Medium
Low
Quiet
High
INDOOR UNIT
Heating
Medium
Low
Quiet
High
Medium
Low
Quiet
1,130 rpm
950 rpm
790 rpm
550 rpm
1,220 rpm
1,060 rpm
900 rpm
630 rpm
870 rpm
920 rpm
1,220 rpm
1,000 rpm
810 rpm
590 rpm
1,260 rpm
1,080 rpm
900 rpm
670 rpm
870 rpm
920 rpm
ELECTRICAL DATA
INDOOR UNIT
Cooling
INDOOR UNIT
Heating
OUTDOOR
UNIT
Heating
AIRFLOW
High
Medium
Low
Quiet
Cooling
OUTDOOR
UNIT
Heating
Cooling
High
Medium
Low
Quiet
INDOOR UNIT
Cooling
INDOOR UNIT
Heating
OUTDOOR
UNIT
Heating
NOISE LEVEL
40 dB
35 dB
30 dB
High
Medium
Low
42 dB
38 dB
33 dB
21 dB
Quiet
19 dB
50 dB
Cooling
50 dB
43 dB
36 dB
30 dB
44 dB
39 dB
33 dB
24 dB
20 dB
50 dB
50 dB
2017.09.21 2
COMPRESSOR TYPE
Hermetic motor compressor,
Single rotary,
BLDC motor, 6 pole
DISCRIMINATION DA092MJB
PRECHARGED REFRIGERANT
REFRIGERANT TYPE R32
850 g
850 g
WEIGHT (with oil)
7.65 kg
DA102MJC
7.65 kg
COMPRESSOR AND REFRIGERANT
Pipe length
15 m
FULL CHARGE
20 m 950 g
MAXIMUM PIPING HEIGHT
15 m
ADDITIONAL CHARGE
20 g/m
WEIGHT
INDOOR UNIT Net / Shipping
Net / Shipping
10 kg / 13 kg
OUTDOOR UNIT
31 kg / 35 kg 32 kg / 36 kg
INDOOR UNIT H x W x D
H x W x D
270 x 834 x 215 mm
OUTDOOR UNIT
542 x 799 x 290 mm
DIMENSIONS