EasyManua.ls Logo

Fujitsu ASYG09KMCB - Page 11

Fujitsu ASYG09KMCB
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The maximum value of the indoor fan speed is set as shown in Fig. based on the detected
temperature by the indoor heat-exchanger sensor on heating mode.
Fig : Cool air prevension control
01-08
6. COOL AIR PREVENTION CONTROL (HEATING MODE)
42°C
30°C
34°C
Indoor heat exchanger
temperature rises
Indoor heat exchanger
temperature drops
Hi
Me+
Lo
Cool air
prevention
39°C
37°C
37°C
32°C
28°C
S-Lo
42°C
30°C
34°C
Indoor heat exchanger
temperature rises
Indoor heat exchanger
temperature drops
Powerful
Hi
Lo
Cool air
prevention
39°C
37°C
37°C
32°C
28°C
S-Lo
<Normal operation>
<Powerful operation>
5. HEATING OPERATION
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as below.
On the other hand, if switched in [Hi] ~ [Quiet], the indoor motor will run at a constant airflow
of [Heat] operation modes Quiet, Lo, Me, Hi, as the previous page.
Fig : Airflow changeover (Heating : Auto)
TR-Ts -1.5°C
-2.5°C > TR-Ts
-1.5°C > TR-Ts -2.5°C
TR-Ts -1°C
-2°C > TR-Ts
-1°C > TR-Ts -2°C
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
Lo mode
Me mode
Me+ mode

Other manuals for Fujitsu ASYG09KMCB

Related product manuals