¢ Wall mounted type (For KMTB, KMTE, KMCC, KMCE, and
KMCF)
• Rotation number range of compressor
Unit: rps
Connected model name Minimum rotation number Maximum rotation number
AOYG18KBTA3
AOYG24KBTA3
10 130
• Limit of maximum speed based on outdoor temperature
A zone
26°C
B zone
C zone
D zone
23°C
20°C
Unit: rps
– Model: AOYG18KBTA3
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASYG07–14KMTB
ASYG07–14KMCC
ASYG07–14KMCE
ASYG07–14KMCF
A zone 102 74 63 54
B zone 102 87 74 63
C zone 130 111 94 80
D zone 130 130 130 130
– Model: AOYG24KBTA3
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASYG07–18KMTB
ASYG18KMTE
ASYG07–14KMCC
ASYG07–14KMCE
ASYG07–14KMCF
A zone 102 74 63 54
B zone 102 87 74 63
C zone 130 111 94 80
D zone 130 130 130 130
1-1. Cooling operation - (04-6) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS