EasyManua.ls Logo

Fujitsu AUXB24GALH - User Manual

Fujitsu AUXB24GALH
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SERVICE MANUAL

Table of Contents

Other manuals for Fujitsu AUXB24GALH

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXB24GALH and is the answer not in the manual?

Fujitsu AUXB24GALH Specifications

General IconGeneral
BrandFujitsu
ModelAUXB24GALH
CategoryAir Conditioner
LanguageEnglish

Summary

TEST RUN

Pre-Power ON and Post-Power ON Checks

Lists critical items to check before and after applying power, covering installation, safety, and system status verification.

1-3 TEST RUN CONTROL

Describes test run control parameters like operating modes, fan speed, temperature indication, and air direction settings.

OUTDOOR UNIT OPERATION CONTROL

2-2 COMPRESSOR OPERATION

Explains compressor operation, stop conditions, capacity control, and speed ranges for start, stop, and continuous operation.

2-3 FAN CONTROL

Details fan control for cooling, heating, and low noise modes, including fan steps, switching conditions, and sound reduction.

2-4 EXPANSION VALVE CONTROL

Describes expansion valve control for EEV1 and EEV2, covering initialization, operation, and special control modes.

2-5 SPECIAL OPERATION

Explains special operations like oil recovery, pre-heat, and defrost control for system maintenance and protection.

2-6 PROTECTIVE FUNCTION

Lists protective functions, including temperature, high/low pressure, and abnormal protections for safe system behavior.

INDOOR UNIT OPERATION

3-1 FAN CONTROL

Covers fan control for indoor units, including speed settings, AUTO position logic, and operation during DRY mode.

3-2 MASTER CONTROL

Explains master control functions: operation mode, priority modes, auto changeover, and COOL/HEAT positions.

3-3 LOUVER CONTROL

Provides instructions for adjusting air circulation direction (vertical/horizontal louvers) and swing operations using the remote control.

3-4 ELECTRONIC EXPANSION VALVE CONTROL

Details electronic expansion valve control for indoor units, including initialization, operation, and special controls.

3-5 DRAIN PUMP OPERATION

Explains drain pump operation, covering starting, stopping, and float switch functions for indoor units.

TROUBLE SHOOTING

4-2 ABNORMAL OPERATION

Details abnormal operation indicators for indoor and outdoor units, listing error contents, flashing patterns, and troubleshooting references.

DISASSEMBLY PROCESS

Related product manuals