2-4. E: 18. External communication error (Indoor unit)
Indicator Indoor unit
Operation indicator 1 time flash
Timer indicator 8 time flash
Economy indicator Continuous flash
Error code E: 18
Detective actuator Indoor unit
External
communication
error
After receiving a signal from the external input and
output PCB, the same signal has not been received for
15 seconds.
Forecast of cause
Connection failure
WLAN adapter failure
Main PCB
Check point 1. Check the connection
Check any loose or removed connection between the main PCB to the WAN adapter.
-> If there is an abnormal condition, correct it by refer to the installation manual or the “DESIGN
& TECHNICAL MANUAL”.
Check the connection condition on the WLAN adapter and the main PCB (If there is loose con-
nector, open cable or mis-wiring.)
Check point 2. Replace the WLAN adapter
If check point 1 do not improve the symptom, change WLAN adapter.
Check point 3. Replace the main PCB
If check point 2 do not improve the symptom, replace the main PCB.
End
2-4. E: 18. External communication error (Indoor unit) - (03-17) - 2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu AUXG07KVLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXG07KVLA and is the answer not in the manual?

Fujitsu AUXG07KVLA Specifications

General IconGeneral
BrandFujitsu
ModelAUXG07KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals