2-27. E: 65. Trip terminal L error (Outdoor unit)
Indicator Indoor unit
Operation indicator 6 time flash
Timer indicator 5 time flash
Economy indicator Continuous flash
Error code E: 65
Detective actuator Outdoor unit Main PCB
When the signal from FO terminal of IPM is ā€œLā€ (0 V)
during the compressor stopping.
Forecast of cause Main PCB failure
Check point 1. Check main PCB
Replace the outdoor unit main PCB.
↓
End