EasyManuals Logo

Fujitsu AUXG14KVLA User Manual

Fujitsu AUXG14KVLA
403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #286 background imageLoading...
Page #286 background image
1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
18°C
E zone
12°C
D zone
7°C
C zone
B zone
A zone
-3°C
-8°C
G zone
22°C
H zone
38°C
Unit: rps
Model name Outdoor temperature zone
Limitation of compressor
rotation number
AOHG14KBTA2
A zone 40
B zone 25
C zone 25
D zone 19
E zone 19
F zone 19
G zone 18
H zone 23
AOHG18KBTA2
A zone 30
B zone 30
C zone 23
D zone 18
E zone 13
F zone 11
G zone 11
H zone 25
1-5. Rotation number of compressor limitation by outdoor temperature - (04-24) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AUXG14KVLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXG14KVLA and is the answer not in the manual?

Fujitsu AUXG14KVLA Specifications

General IconGeneral
BrandFujitsu
ModelAUXG14KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals