¢ Wall mounted type (For KETE)
• Rotation number range of compressor
Unit: rps
Connected model name Minimum rotation number Maximum rotation number
AOHG14KBTA2 12 89
AOHG18KBTA2 8 94
• Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
– Model: AOHG14KBTA2
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASHG07KETE
ASHG07KETE-B
A zone 89 50 38 18
B zone 89 50 38 18
C zone 50 38 34 18
D zone 38 34 30 18
E zone 38 34 30 18
F zone 38 34 30 18
ASHG09KETE
ASHG09KETE-B
ASHG12KETE
ASHG12KETE-B
ASHG14KETE
ASHG14KETE-B
A zone 89 50 38 14
B zone 89 50 38 14
C zone 50 38 34 14
D zone 38 34 30 14
E zone 38 34 30 14
F zone 38 34 30 14
1-1. Cooling operation - (04-11) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AUXG14KVLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXG14KVLA and is the answer not in the manual?

Fujitsu AUXG14KVLA Specifications

General IconGeneral
BrandFujitsu
ModelAUXG14KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals