¢ Wall mounted type (For KGTE)
Rotation number range of compressor
Unit: rps
Model: AOHG14KBTA2
Model name Outdoor temperature zone Operating rotation number
ASHG07KGTE
X zone 18
J zone 18
Y zone 0
ASHG09KGTE
ASHG12KGTE
ASHG14KGTE
X zone 14
J zone 14
Y zone 0
Model: AOHG18KBTA2
Model name Outdoor temperature zone Operating rotation number
ASHG07KGTE
X zone 14
J zone 14
Y zone 0
ASHG09KGTE
ASHG12KGTE
ASHG14KGTE
X zone 10
J zone 10
Y zone 0
Compressor control based on room temperature
Ts+0.5°C
Ts -1.5°C
Ts-0.5°C
Ts+1.5°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature