 Overflow control
• Triggering condition
The float switch is turned on.
• Operation details
– The drain pump is turned on.
– When the operation mode is cooling or dry, operate the followings.
• The compressor is stopped.
• Then indoor fan control is turned off.
• Release condition
– The float switch is turned off.
• In the case that on the cooling or dry mode the thermostat is on, refer to "During the com-
pressor in operation" for the operation after release.
• In other case, refer to "When the compressor is not in operation" for the operation after
release.
– 3 minutes passed
• Operation after release
The compressor stopps permanently.
 The compressor is stopped by Anti-freezing control
• Triggering condition
During the compressor in operation, the compressor is stopped by Anti-freezing control.
• Operation details
The drain pump is kept on in 60 minutes after Anti-freezing control released.
• Release condition
60 minutes passed
• Operation after release
According to the settings, operate the followings.
On
Off
On
Off
On
Off
a. Operation at
anti-freezing
b. Operation when
cooling mode is
stopped
Operation at
a. and b.
60
3
7
3 3
47
3
117
(min)
3
2
3
60
117
Anti-freezing start
Stopped
Release
freezing
7-11. Drain pump control - (04-79) - 7. Various control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AUXG14KVLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXG14KVLA and is the answer not in the manual?

Fujitsu AUXG14KVLA Specifications

General IconGeneral
BrandFujitsu
ModelAUXG14KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals