7. Safety devices
Type of
protection
Protection form
Model
ASHG07KMCC ASHG09KMCC ASHG12KMCC
Circuit
protection
Current fuse (PCB*) 250 V, 3.15 A
Fan motor
protection
Thermal protection
Activate
170
+25
-30
°C
Fan motor stop
Reset
145
+25
-30
°C
Fan motor restart
Type of
protection
Protection form
Model
ASHG14KMCC
Circuit
protection
Current fuse (PCB*) 250 V, 3.15 A
Fan motor
protection
Thermal protection
Activate
170
+25
-30
°C
Fan motor stop
Reset
145
+25
-30
°C
Fan motor restart
*PCB: Printed Circuit Board