EasyManua.ls Logo

Fujitsu General ASGA18SEFT - User Manual

Fujitsu General ASGA18SEFT
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
WALL MOUNTED TYPE
Cooling Only Model
壁掛式
冷氣型專用
LOI TREO TƯỜNG
Kiu máy ch làm lnh
TIPE DIPASANG DI DINDING
Model Pendinginan Saja
Indoor unit
室內機
Dàn lnh
Unit dalam-ruang
ASGA18SEFT
ASGA24SEFT
Outdoor unit
室外機
Dàn nóng
Unit luar-ruang
AOGA18SEFTH
AOGA24SEFTH
OPERATION MANUAL
English
PART No. 9385989467
Vit
Indonesia
HƯỚNG DN VN HÀNH
BUKU PANDUAN PENGOPERASIAN
KEEP THIS MANUAL FOR FUTURE REFERENCE
請保存本說明書以供日後參考
VUI LÒNG GI LI SÁCH HƯỚNG DN NÀY ĐỂ THAM KHO TRONG TƯƠNG LAI
SIMPAN PANDUAN INI UNTUK REFERENSI MENDATANG
中國語
9385989467_OM.indb 19385989467_OM.indb 1 10/21/2020 1:28:29 PM10/21/2020 1:28:29 PM
Question and Answer IconNeed help?

Do you have a question about the Fujitsu General ASGA18SEFT and is the answer not in the manual?

Overview

This document is an operation manual for a Fujitsu General Limited wall-mounted, cooling-only air conditioner. It covers various aspects of the device, including its functions, technical specifications, usage, and maintenance.

Function Description

The air conditioner is designed for cooling-only operation, providing comfort through various modes and features.

Cooling Operation: The primary function is cooling, with the ability to adjust fan speed and thermostat settings to achieve desired room temperatures.

AUTO CHANGEOVER: This feature automatically switches between cooling and dry modes to maintain the set temperature, ensuring constant comfort.

OMNI-DIRECTIONAL AIRFLOW (SWING OPERATION): The unit offers a 3-dimensional control over air direction. This includes UP/DOWN and RIGHT/LEFT airflow direction swing. The swing operation can be set to up/down, left/right, or a combination of both, directing airflow to a wide area.

HORIZONTAL AIRFLOW: COOLING: For cooling, the unit uses horizontal airflow to ensure the cool air does not blow directly on occupants.

POWERFUL OPERATION: This mode allows the air conditioner to operate at maximum fan speed and a lower thermostat setting (1°C lower than the setting) to quickly cool down a room. The indoor unit's airflow is adjusted automatically to direct air at an angle that the wind usually blows on the user. The fan speed returns to its original setting after 30 minutes.

SUPER QUIET OPERATION: When activated, the indoor unit's airflow is reduced for quieter operation. This mode is not available during Dry mode. Cooling performance may be slightly reduced in this mode.

SLEEP TIMER OPERATION: This function automatically modifies the thermostat setting to prevent excessive cooling during sleep. During Cooling/Dry operation, the thermostat setting is raised by 1°C every hour, up to a total of 2°C, and maintained until the set time elapses, after which the air conditioner turns off.

PROGRAM TIMER: The program timer allows for the integration of OFF timer and ON timer operations in a single sequence within a 24-hour period. This means the unit can be set to automatically stop (OFF timer) and then start (ON timer) at specified times.

AIR CLEANING FILTER: The unit can be equipped with optional air cleaning filters, including an APPLE-CATECHIN FILTER and an ION DEODORIZATION FILTER, to improve air quality.

MILDEW-RESISTANT FILTER: The air filter has been treated to resist mildew growth, promoting cleaner and easier care.

APPLE-CATECHIN FILTER (OPTION): This filter uses static electricity to clean fine particles and dust, as well as tobacco smoke and plant pollen.

ION DEODORIZATION FILTER (OPTION): This filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

REMOVABLE INTAKE GRILLE: The indoor unit's intake grille can be removed for easy cleaning and maintenance.

AUTO RESTART: In the event of a power interruption, the air conditioner will automatically restart in its previous mode once power is restored. If a power interruption occurs during TIMER operation, the timer will be reset, and the indoor unit will begin (or stop) operation at the new time setting.

Important Technical Specifications

Models:

  • Indoor Unit: ASGA18SEFT, ASGA24SEFT
  • Outdoor Unit: AOGA18SEFTH, AOGA24SEFTH

Power Supply:

  • 220-230-240V ~ 50Hz

Cooling Capacity:

  • ASGA18SEFT/AOGA18SEFTH: 5.40 - 5.40 - 5.40 kW
  • ASGA24SEFT/AOGA24SEFTH: 7.15 - 7.15 - 7.15 kW

Input Power (Cooling):

  • ASGA18SEFT/AOGA18SEFTH: 1.79 - 1.82 - 1.87 kW
  • ASGA24SEFT/AOGA24SEFTH: 2.44 - 2.49 - 2.60 kW

Current (Max.):

  • ASGA18SEFT/AOGA18SEFTH: 8.2 / 8.2 / 8.2 (13.0) A
  • ASGA24SEFT/AOGA24SEFTH: 11.8 / 12.0 / 12.6 (17.5) A

Energy Efficiency Ratio (EER):

  • ASGA18SEFT/AOGA18SEFTH: 3.02 - 2.97 - 2.89 kW/kW
  • ASGA24SEFT/AOGA24SEFTH: 2.93 - 2.87 - 2.75 kW/kW

Max. Pressure:

  • Suction: 1.20 MPa
  • Discharge: 4.20 MPa

Refrigerant (R410A):

  • ASGA18SEFT/AOGA18SEFTH: 1.10 kg
  • ASGA24SEFT/AOGA24SEFTH: 1.55 kg

Dimensions (H x W x D):

  • Indoor Unit: 320 x 998 x 238 mm
  • Outdoor Unit: 650 x 830 x 320 mm

Weight:

  • Indoor Unit: 13 kg
  • Outdoor Unit (ASGA18SEFT/AOGA18SEFTH): 47 kg
  • Outdoor Unit (ASGA24SEFT/AOGA24SEFTH): 55 kg

Operating Temperature Range:

  • Outdoor Temperature (Cooling/Dry): 21 to 52 °C
  • Indoor Temperature (Cooling/Dry): 18 to 32 °C
  • Indoor Humidity: 80% or less

Noise Information: The maximum sound pressure level is less than 70 dB (A) for both indoor and outdoor units, according to IEC 704-1 and ISO 3744.

Usage Features

Remote Controller: The unit is operated via a wireless remote controller, which allows for setting the mode, fan speed, temperature, and timer functions. The remote controller display shows the current operation mode, temperature, fan speed, swing status, timer mode, and clock.

Manual Auto Operation: In case the remote controller is lost or unavailable, the unit can be operated manually using a button on the indoor unit's control panel. This will operate the unit in AUTO mode with "AUTO" fan speed and a standard thermostat setting of 24°C.

Adjusting Airflow Direction:

  • Vertical Air Direction: Adjustable using the SET button (Vertical) on the remote controller, with 6 possible ranges. The vertical airflow direction is set automatically based on the operation mode (horizontal flow for Cooling/Dry/Fan, and horizontal for the first minute of AUTO mode).
  • Horizontal Air Direction: Adjustable using the SET button (Horizontal) on the remote controller, with 5 possible ranges.

Timer Operations:

  • ON/OFF Timer: Allows setting a specific time for the unit to turn ON or OFF.
  • Program Timer: Combines ON and OFF timer operations in a sequence.
  • Sleep Timer: Automatically adjusts the thermostat setting during sleep and turns off the unit after a set period.

Custom Code Selection: If multiple air conditioners are installed in one room, the remote controller's custom code can be changed (A, B, C, D) to operate only the desired unit.

Maintenance Features

Cleaning the Intake Grille: The intake grille can be easily removed for cleaning. It involves pulling the lower ends of the grille panel, unhooking the intermediate catch, and pulling it upward to remove.

Cleaning the Air Filter: The air filter should be cleaned regularly. It can be removed by lifting the intake grille, disconnecting the lower tabs, and pulling it out. Dust can be removed with a vacuum cleaner or by washing with water and drying in the shade.

Air Cleaning Filter Maintenance (Optional):

  • APPLE-CATECHIN FILTER: Disposable and should be exchanged approximately every 3 months.
  • ION DEODORIZATION FILTER: Should be exchanged approximately every 3 years. To maintain its deodorizing effect, it should be cleaned with water every 3 months. This involves removing the filter, flushing it with high-pressure hot water or diluted neutral detergent, rinsing, and drying in the shade before reinstalling.

General Maintenance:

  • Provide occasional ventilation during use.
  • Always operate with air filters installed.
  • Turn off the power source when not using the product for extended periods.
  • After long periods of use, check the installation stand for deterioration.
  • Keep the area around the outdoor unit clean and tidy to prevent small animals or insects from infiltrating and causing malfunctions.
  • Do not pull the power supply cable.
  • Do not touch the aluminum fins of the heat exchanger to avoid injury.
  • Consult authorized service personnel for repairs, installation, and relocation.