Do you have a question about the Fujitsu General ASGA18SEFT and is the answer not in the manual?
This document is an operation manual for a Fujitsu General Limited wall-mounted, cooling-only air conditioner. It covers various aspects of the device, including its functions, technical specifications, usage, and maintenance.
The air conditioner is designed for cooling-only operation, providing comfort through various modes and features.
Cooling Operation: The primary function is cooling, with the ability to adjust fan speed and thermostat settings to achieve desired room temperatures.
AUTO CHANGEOVER: This feature automatically switches between cooling and dry modes to maintain the set temperature, ensuring constant comfort.
OMNI-DIRECTIONAL AIRFLOW (SWING OPERATION): The unit offers a 3-dimensional control over air direction. This includes UP/DOWN and RIGHT/LEFT airflow direction swing. The swing operation can be set to up/down, left/right, or a combination of both, directing airflow to a wide area.
HORIZONTAL AIRFLOW: COOLING: For cooling, the unit uses horizontal airflow to ensure the cool air does not blow directly on occupants.
POWERFUL OPERATION: This mode allows the air conditioner to operate at maximum fan speed and a lower thermostat setting (1°C lower than the setting) to quickly cool down a room. The indoor unit's airflow is adjusted automatically to direct air at an angle that the wind usually blows on the user. The fan speed returns to its original setting after 30 minutes.
SUPER QUIET OPERATION: When activated, the indoor unit's airflow is reduced for quieter operation. This mode is not available during Dry mode. Cooling performance may be slightly reduced in this mode.
SLEEP TIMER OPERATION: This function automatically modifies the thermostat setting to prevent excessive cooling during sleep. During Cooling/Dry operation, the thermostat setting is raised by 1°C every hour, up to a total of 2°C, and maintained until the set time elapses, after which the air conditioner turns off.
PROGRAM TIMER: The program timer allows for the integration of OFF timer and ON timer operations in a single sequence within a 24-hour period. This means the unit can be set to automatically stop (OFF timer) and then start (ON timer) at specified times.
AIR CLEANING FILTER: The unit can be equipped with optional air cleaning filters, including an APPLE-CATECHIN FILTER and an ION DEODORIZATION FILTER, to improve air quality.
MILDEW-RESISTANT FILTER: The air filter has been treated to resist mildew growth, promoting cleaner and easier care.
APPLE-CATECHIN FILTER (OPTION): This filter uses static electricity to clean fine particles and dust, as well as tobacco smoke and plant pollen.
ION DEODORIZATION FILTER (OPTION): This filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
REMOVABLE INTAKE GRILLE: The indoor unit's intake grille can be removed for easy cleaning and maintenance.
AUTO RESTART: In the event of a power interruption, the air conditioner will automatically restart in its previous mode once power is restored. If a power interruption occurs during TIMER operation, the timer will be reset, and the indoor unit will begin (or stop) operation at the new time setting.
Models:
Power Supply:
Cooling Capacity:
Input Power (Cooling):
Current (Max.):
Energy Efficiency Ratio (EER):
Max. Pressure:
Refrigerant (R410A):
Dimensions (H x W x D):
Weight:
Operating Temperature Range:
Noise Information: The maximum sound pressure level is less than 70 dB (A) for both indoor and outdoor units, according to IEC 704-1 and ISO 3744.
Remote Controller: The unit is operated via a wireless remote controller, which allows for setting the mode, fan speed, temperature, and timer functions. The remote controller display shows the current operation mode, temperature, fan speed, swing status, timer mode, and clock.
Manual Auto Operation: In case the remote controller is lost or unavailable, the unit can be operated manually using a button on the indoor unit's control panel. This will operate the unit in AUTO mode with "AUTO" fan speed and a standard thermostat setting of 24°C.
Adjusting Airflow Direction:
Timer Operations:
Custom Code Selection: If multiple air conditioners are installed in one room, the remote controller's custom code can be changed (A, B, C, D) to operate only the desired unit.
Cleaning the Intake Grille: The intake grille can be easily removed for cleaning. It involves pulling the lower ends of the grille panel, unhooking the intermediate catch, and pulling it upward to remove.
Cleaning the Air Filter: The air filter should be cleaned regularly. It can be removed by lifting the intake grille, disconnecting the lower tabs, and pulling it out. Dust can be removed with a vacuum cleaner or by washing with water and drying in the shade.
Air Cleaning Filter Maintenance (Optional):
General Maintenance: