5. Fan performance
5-1. Air velocity distributions
¢
Models: ASHG07KGTA, ASHG09KGTA, ASHG07KGTB, and
ASHG09KGTB
Measuring conditions
Fan speed Operation mode
HIGH FAN
Top view
Vertical airflow direction louver: Up
Horizontal airflow direction louver: Center
(m)
-3
-2
-1
0
1
2
3
0.52.0 1.0
Unit: m/s
(m)
0 1 2 3 4 5 6 7 8 9 10
Top view
Vertical airflow direction louver: Up
Horizontal airflow direction louver: Left & Right
2.0
2.0
1.0
1.0
0.5
0.5
Unit: m/s
(m)
(m)
-3
-2
-1
0
1
2
3
0 1 2 3 4 5 6 7 8 9 10
Side view
Vertical airflow direction louver: Up
Horizontal airflow direction louver: Center
(m)
(m)
3
2
1
0
0 1 2 3 4 5 6 7 8 9 10
Unit: m/s
2.0
0.5
1.0
Side view
Vertical airflow direction louver: Down
Horizontal airflow direction louver: Center
(m)
(m)
3
2
1
0
0 1 2 3 4 5 6 7 8 9 10
0.50.5
2.0
1.0
Unit: m/s
- 10 -