EasyManua.ls Logo

Fujitsu GENERAL ASHG18KLCA - Heating Capacity

Fujitsu GENERAL ASHG18KLCA
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ASHG18KLCA
AFR
m
3
/h
995
Indoor temperature
16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 4.29 1.49 4.18 1.52 4.07 1.55 3.96 1.58 3.85 1.61
-10 -11 4.97 1.60 4.84 1.63 4.71 1.65 4.58 1.70 4.45 1.73
-5 -7 5.74 1.73 5.59 1.77 5.44 1.77 5.29 1.84 5.14 1.87
0 -2 6.67 1.88 6.49 1.92 6.32 1.93 6.14 2.00 5.97 2.04
5 3 7.41 2.01 7.21 2.05 7.02 2.09 6.83 2.13 6.63 2.17
7 6 8.09 2.09 7.88 2.13 7.67 2.18 7.46 2.22 7.25 2.26
10 8 8.47 2.17 8.25 2.21 8.03 2.24 7.81 2.31 7.59 2.35
15 10 8.46 2.00 8.24 2.04 8.02 2.09 7.80 2.12 7.57 2.16
20 15 7.85 1.56 7.64 1.59 7.44 1.63 7.23 1.66 7.03 1.69
24 18 8.24 1.55 8.03 1.59 7.81 1.62 7.59 1.65 7.38 1.68
¢
Model: ASHG24KLCA
AFR
m
3
/h
1,040
Indoor temperature
16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 6.90 2.74 6.72 2.79 6.54 2.85 6.36 2.90 6.18 2.96
-10 -11 7.98 3.08 7.77 3.14 7.56 3.14 7.35 3.27 7.14 3.33
-5 -7 8.79 3.25 8.56 3.31 8.33 3.40 8.10 3.45 7.87 3.51
0 -2 9.20 3.16 8.96 3.22 8.72 3.31 8.48 3.35 8.24 3.42
5 3 9.53 2.89 9.28 2.95 9.03 3.01 8.78 3.07 8.53 3.13
7 6 9.50 2.55 9.25 2.60 9.00 2.66 8.75 2.71 8.50 2.76
10 8 9.54 2.45 9.29 2.50 9.04 2.59 8.79 2.60 8.54 2.65
15 10 9.60 2.24 9.35 2.29 9.10 2.38 8.84 2.38 8.59 2.43
20 15 9.66 2.04 9.41 2.08 9.16 2.17 8.90 2.16 8.65 2.20
24 18 9.71 1.87 9.46 1.91 9.20 1.95 8.95 1.99 8.70 2.03
- 8 -
4-2. Heating capacity 4. Capacity table
WALL MOUNTED
ASHG18, 24KLCA
WALL MOUNTED
ASHG18, 24KLCA

Related product manuals