EasyManuals Logo

Fujitsu Inverter Halcyon AOU9RLS User Manual

Fujitsu Inverter Halcyon AOU9RLS
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
En-17
OPERATING TIPS
Dry Mode
About 14 to 115 °F
About 64 to 90 °F
Outdoor temperature
Indoor temperature
Cooling Mode
About 14 to 115 °F
About 64 to 90 °F
Heating Mode
About 5 to 75 °F
About 86 °F or less
Temperature and Humidity Range
If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary
dwellings.
If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor
unit, and drip onto the floor or other objects underneath. (About 80% or more).
If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device,
the outdoor unit may stop operation for certain period of time.
TYPE HEAT & COOL MODEL
MODEL INDOOR UNIT ASU9RLS ASU12RLS
OUTDOOR UNIT AOU9RLS AOU12RLS
POWER SUPPLY 208/230 V 60 Hz 208/230 V 60 Hz
COOLING
CAPACITY
9000 BTU/h 12000 BTU/h
INPUT POWER 0.52 kW 0.83 kW
CURRENT 2.6 A 3.9 A
HEATING
CAPACITY 12000 BTU/h 16000 BTU/h
INPUT POWER 0.80 kW 1.20 kW
CURRENT 3.7 A 5.5 A
SPECIFICATION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Inverter Halcyon AOU9RLS and is the answer not in the manual?

Fujitsu Inverter Halcyon AOU9RLS Specifications

General IconGeneral
Cooling Capacity (BTU/h)9000
Cooling Capacity (kW)2.64
Heating Capacity (kW)3.52
Voltage (V)208/230
RefrigerantR410A
Heating Capacity (BTU/h)12000
Power Supply1 Phase, 60Hz
Noise Level (Indoor Unit)46 dB(A)
Noise Level (Outdoor Unit)46 dB(A)

Related product manuals