¢ Medium static pressure duct type
• Compressor frequency range
Connected model name Minimum frequency Maximum frequency
AOHG36KBTB 15 rps 98 rps
AOHG45KBTB 17 rps 95 rps
AOHG54KBTB 17 rps 95 rps
• Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
– Model: AOHG36KBTB
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ARXG22KMLA
ARXG24KMLA
A zone 98 64 49 32
B zone 98 64 49 32
C zone 77 49 40 32
D zone 54 40 34 26
E zone 54 40 34 26
F zone 54 40 34 26
– Models: AOHG45KBTB and AOHG54KBTB
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ARXG22KMLA
ARXG24KMLA
A zone 95 66 51 33
B zone 95 66 51 33
C zone 80 51 41 33
D zone 56 41 35 27
E zone 56 41 35 27
F zone 56 41 35 27
1-1. Cooling operation - (01-4) - 1. Compressor frequency control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS