EasyManuals Logo

Fujitsu RSG12LMCA User Manual

Fujitsu RSG12LMCA
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
03-02
( Factory setting)
Setting Description
Function Number Setting Value
No
Yes
42
00
01
1-5. Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by
Wired remote controller temperature sensor.
( Factory setting)
Setting Description
Function Number Setting Value
A
B
C
D
44
00
01
02
03
1-6. Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
( Factory setting)
Setting Description
Function Number Setting Value
Operation/Stop mode
(Setting forbidden)
Forced stop mode
46
00
01
02
1-7. External input control
"Operation/Stop" mode or "Forced stop" mode can be elected.
( Factory setting)
Setting Description
Function Number Setting Value
No
Yes
49
00
01
1-8. Indoor unit fan control for energy saving
Enable or disable indoor unit fan control when the outdoor unit is stopped.
* If setting value is "00" : Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is "01" : Room temperature is controlled by either indoor unit temperature sensor
or remote controller unit sensor.
* If setting value is "00" : When the outdoor unit is stopped, the indoor unit fan operates following the
setting on the remote controller continuously.
* If setting value is "01" : When the outdoor unit is stopped, the indoor unit fan operates at very low speed
intermittently.