6. Troubleshooting
Makesurethepowerisswitchedoffandunpluggedbefore
inspectingorrepairingthemachine!
Problem1: Themachinestillworks,buttheairflowisveryweak
andsuctionpowerisgreatlyreduced.
Cause: AirInletisblockedorforeignbodyexistsinsidetheduct.
The filter becomes saturated and hence gets blocked
and gives an alarm. Usually only the prefilter gets
clogged quickly with large particles and needs to be
vacuumedorreplaced.
Solution: Turnoffthepowerandopenthetopcover.Checkif
there is any foreign objects blocking the air inlet. Then
check if the air vent is blocked or not. If the suction
power of the emptyloaded machine is normal, it means
thefilterneedstobereplaced.
Problem2: Themachineshutsdownautomaticallyafteritisjust
started. Even if you restart the machine, the same
problemhappensagain.
Cause: Theairflowthroughthemachineisobstructed.Asa
result, the starting current of the fan becomes very high,
hence the machine shuts down automatically for self
protection.
Solution: Turnoffthepowerandopenthetopcover.Checkif
thereisanyobstructionsintheairinletorreplacefilters.
Problem3: PowerswitchisON,butmachinedoesnotrunandthe
powerindicatordoesnotlightup.
Cause: Thefusemightbebad.
Solution: The fuse needs to be replaced. Pop the fuse out from
the power socket using a flat head screwdriver and
replace.