current rating | 15 Amps (E versions 10 Amps) |
---|---|
input voltage | 85 to 135 VAC (E versions 190 to 270 VAC) |
voltmeter accuracy | PL-PLUS only: ±2 VAC |
spike clamping voltage | Initial turn-on at 200 Volts; TVSS rating of 400 Volts peak at 500 Amps |
response time | 1 nanosecond |
maximum surge current | 6, 500 Amps |
maximum spike energy | 80 Joules per mode, 240 Joules total protection (E versions 130 Joules L-N, 160 Joules N-G, L-G, 450 Joules total) |
noise attenuation | 20 dB at 200 kHz, rising to >40 dB, 1 to 100 MHz |
power consumption | PL-8, 14 Watts, PL-PLUS, 20 Watts |
---|
dimensions | 1.75” H x 19” W x 8” D |
---|---|
weight | 6 lbs (2.7 kg) |
Details the PL-8's rack illumination, switched outlets, surge protection, RFI/EMI filtering, and circuit breaker.
Highlights the PL-PLUS's voltage monitor (90-128V) and enhanced RFI/EMI noise filter.
Explains the PL-PLUS's 20-LED voltage meter and its low-pass RFI/EMI filter for noise reduction.
Describes specifications for international models with 220-240V input, 10 rear outlets, and 10 Amp rating.
Details how the unit protects against lightning strikes and incorrect voltage connections, including 'suicide mode'.
Defines power line spikes, their causes, and protection, along with RFI/EMI interference and filtering.
Outlines the warranty terms, coverage, exclusions, and service procedures for the product.
Lists key technical data: current rating, input voltage, surge protection, response time, and dimensions.