EasyManua.ls Logo

Furman PL-Pro-E User Manual

Furman PL-Pro-E
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PL-PRO POWER CONDITIONER AND LIGHT MODULEPL-PRO POWER CONDITIONER AND LIGHT MODULE
1
Owner’s Manual
MODEL PL-PRO
3-9918 © 1997 FURMAN SOUND, INC. 960110-1405
PRO SERIES
Power Conditioner
and Light Module
MODEL PL-PRO-E
12
PL-PRO, PL-PRO-E SPECIFICATIONS
Note: Where different, PL-PRO-E specs are in parentheses.
Current rating: 20 Amps, 2400 watts at 120 VAC
(16 Amps, 3600 watts at 230 VAC)
Input Voltage Range: 0 to 280 VAC without damage
Meter Accuracy: Voltmeter: ± 2 (±4) VAC; Ammeter: ± 2 amps,
calibrated with trimpot adjustments
Spike Protection Modes: Line to neutral, neutral to ground, line to ground
Clamping Voltage, all modes: TVSS rating 400V peak, L-N, L-G, N-G, tested
to UL 1449 (TVSS rating 400V peak, L-N; 680V
peak, L-G, N-G)
Response time: 1 nanosecond
Maximum surge current: 11,000 amps (8 x 20mS pulse)
Maximum spike energy: 550 joules total
Noise attenuation: Differential mode: Greater than 40 dB;
Common mode: greater than 60 dB;
both 1 to 200 MHz
Dimensions: 1.75" (4.45 cm) H x 19" (48.25 cm) W
x 8" (25 cm) D.
Weight: 6 lbs (2.7 kg).
Construction: Steel chassis, zinc chromate plating;
brushed and black anodized aluminum
front panel; glass epoxy printed circuit boards.
Power consumption: 32 watts
Safety Information: PL-PRO: UL listed. CUL listed.
PL-PRO-E: CE
Options: “-G” Suffix (PL-PRO only): provides “super
spec”, isolated ground 120V outlets for special
applications. Please consult factory before
ordering to determine suitability in your
application.
The Furman PL-PRO is made in the U.S.A.
Furman Sound, Inc.
1997 South McDowell Blvd.
Petaluma, California 94954-6919
Phone: (707) 763-1010
Fax: (707) 763-1310
Web: www.furmansound.com
E-mail: info@furmansound.com
Question and Answer IconNeed help?

Do you have a question about the Furman PL-Pro-E and is the answer not in the manual?

Furman PL-Pro-E Specifications

General IconGeneral
Input Voltage120V
Input ConnectorNEMA 5-15P
Input Current15A
Maximum Output Current15A
Output ConnectorsNEMA 5-15R
Surge ProtectionYes
Noise FiltrationYes
FilteringYes
Circuit BreakerYes
Rack Space1U
Rack MountableYes
Front Panel MeteringYes
Front Panel LampYes
TypePower Conditioner
Outlets8

Summary

PL-PRO PL-PRO-E Specifications

Three Year Limited Warranty

Service Information

Safety Information

Important Safety Instructions

Read and observe all safety and operating instructions before using the PL-PRO. Retain for future reference.

Introduction to PL-PRO Series

Understanding Lightning Effects and Protection

PL-PRO vs. PL-PRO-E Comparison

Front Panel Controls and Indicators

Dimmer Control

Controls the brightness of the front panel light fixtures. Turn clockwise to increase brightness.

Protection OK Indicator

Indicates the integrity of the protection devices. If not lit, protection is compromised or not functioning.

Ground OK Indicator

Monitors grounding integrity. If not lit, the unit is not properly grounded. Not available on PL-PRO-E.

Extreme Voltage Shutdown Indicator

Alerts to hazardous voltage levels (low or high) that cause power shutdown to protect equipment.

Light Tubes and Replacement

Details on the slide-out rack lights, their operation, and how to replace the bulbs.

LED Voltmeter Display

A 20-LED bargraph voltmeter providing real-time AC voltage readings and indicating abnormal power conditions.