3. SETTINGS AND ADJUSTMENTS
22
[Max Engine Boost Pres-
sure]
Set the maximum pressure for en-
gine boost.
[160 kPa], [200 kPa], [320 kPa]
[Max Engine Coolant Pres-
sure]
Set the maximum pressure for en-
gine coolant.
[320 kPa], [520 kPa], [600 kPa]
[Max Fuel Pressure] Set the maximum pressure for fu-
el.
[320 kPa], [520 kPa], [600 kPa]
[Engine Temperature] Set the operational temperature
range for the engine(s).
[86 to 320 °F], [122 to 410 °F]
[Engine Oil Temperature] Set the safe temperature range
for the engine oil.
[86 to 320 °F], [122 to 410 °F]
[Transmission Tempera-
ture]
Set the operational temperature
range for the transmission.
[86 to 320 °F], [122 to 410 °F]
[Engine Setup] tab
[Engines] Set the number of engines fitted
to your vessel.
[1] to [4]
[Manual Fuel Management] tab
[Manual Management] Select whether or not to manual
manage your fuel.
[ON], [OFF]
[Total Fuel Capacity] Set the total fuel capacity for your
vessel.
[0] to [9999] (US gal)
[NMEA Output Instance] Select the output instance for fuel
data.
[0] to [5]
Note: The remaining fuel calculation is for reference purposes. Do not use the results for navigation
planning or emergency purposes. During an entire voyage, select one GP-1x71F unit for the calcu-
lation at start-up and keep that unit powered. The calculation of remaining fuel is not done when the
unit is powered off.
[IF NMEA Setup tab]
[Select IF] Select the interface unit to use. -
[Category] Select the category of the analog
sensor.
[Wind], [ST800/ST850], [Fuel],
[Fresh Water], [Waste Water],
[Live Well], [Oil], [Black Water]
[Resistance Full] Set the resistance of the tank at
full.
[0 ohm] to [500 ohm]
[Resistance Mid] Set the resistance of the tank at
half-full.
[0 ohm] to [500 ohm]
[Resistance Empty] Set the resistance of the tank at
empty.
[0 ohm] to [500 ohm]
[Capacity] Set the maximum capacity of the
tank.
[0] to [9999]
[Self Test] Start a diagnostic test of the de-
vices connected via the IF NMEA.
-
[Refresh] Refresh the list of connected de-
vices
-
[Rudder Setup] tab
[PORT/STBD Reversing] Select whether or not to set port
and starboard in reverse.
[ON], [OFF]
[About] tab - [System Information]
[Software Version] Software version for the GP-1x71F.
[Boot Version] Boot application version.
[Kernel Version] Kernel application version.
[RootFS Version] RootFS application version.
[Cartography] Method of cartography.
Menu name Description Setting range/options
3. SETTINGS AND ADJUSTMENTS
23
3. Tap the [u] icon at the top-right corner of the menu to close the menu.
[Chart 1] Type of chart used for Chart 1.
[Chart 2] Type of chart used for Chart 2.
[About] tab - [Fish Finder Information]
[Serial Number] Serial number of the connected transducer.
[Program Version] Fish Finder program version.
[Boot Version] Boot application version.
[FPGA Version] FPGA version.
[FPGA Program Version] FPGA program version.
[About] tab - [C-Weather Information]
[C-Weather] C-Weather version.
[About] tab - [About OSS]
[About OSS] Shows the open-source software information for your GP-1871F/
1971F.
[About] tab - [Copyright]
[Copyright] Shows the copyright information for your GP-1871F/1971F.
[Service] tab
[Open Test Page] Open the diagnostics test page. A password is required to access this
menu.
[Restore Defaults] tab
[Restore Default Settings] Select whether or not to restore
the [Initial Setup] menu’s default
settings.
[Yes], [No]
[Restore All to Factory De-
faults]
Select whether or not to restore
all menu settings to default.
Note: User settings are not affect-
ed by this menu.
[Yes], [No]
[Clear Memory] tab
[Clear] Select whether or not to clear the
memory and restore all settings to
default.
Note: All user settings and data
will also be cleared.
[Yes], [No]
Menu name Description Setting range/options