D
ATA
S
ETTING
Gyro Reverse
Initial value: NOR
Sets the gyro operation direction. NOR or REV can be selected.
Set so that when the helicopter is banked right, left correction rud
-
der is applied and when the helicopter is banked left, right correction
rudder is applied.
Gyro Gain Adjustment
Initial value: 100%
Adjusts the gyro gain. Setting range is 0 to 120%.
Two-point (G:1, G:2) gain adjustment is possible. When A is dis
-
played, the gyro is in the AVC mode and when N is displayed, the
gyro is in the NOR mode in accordance with the operation mode set
-
ting.