System Lockout Screen - When entering the menu screens,
if there is a lockout code this screen will appear. You must
enter the system password to be able to go any further into the
menu screens. If this option is not needed it may be disabled
in the installation menu. Password is Factory set to 1000
Filtering - Changing the ltering rate can help to cure any
jumpy behavior of the receiver. The best setting is the fastest
setting with the least amount of interruptions.
Valve Dead band - Is the amount of allowable on-grade tol-
erance. The range is 1mm to 30mm at 1mm steps. When the
receiver is receiving the laser light in the on-grade position, the
valves will not activate until the dead band range is passed. If
the on-grade dead band is set to 10mm, the valves will not be
activated until the receiver readings are beyond 5mm in either
direction.
Horn - Sets the function of the internal beeper. Off: disables
the internal beeper. Alert: sets the beeper to grade alarm
mode, when in automatic, if there is no on-grade indication for
6 seconds the alarm will sound. Indicate: sets the beeper to
indicate mode, the grade lights sounds the beeper like a detec-
tor. If the to high you get a double beep, low a single beep and
on grade a solid beep.
Height Adjustment - By setting the Height adjustment option
to “ON”, the off-set knob is enabled and the user has the ability
to have an adjustable ‘on grade’ which is displayed on the LCD.
If the Height adjustment is off or Height set to “0”, the off-set
knob is disabled and the ‘Real Time’ blade position is displayed
on the LCD.
Unit selection - Sets for 3 different units: Millimeters, Inches
(decimal inches) or Feet (10th of a foot).
Latec Info Screen - The nal screen in the menu displays
Latec Info, Name and phone number. Outside of North Ameri-
ca, dial +01.519.235.4585.
Note:
To access the Installation Menu , press the Menu
and Power button in UNISON while the LATEC info
screen is displayed.