Original Bedienungsanleitung FUXTEC FX-IG13_de_en_fr_ita_rev04
32
17 TROUBLE SHOOTING
• Incorrect starting sequence
• Observe the correct starting
sequence
• Clean/replace air cleaner
• Check the fuel line for kinks
or damages
• Screw off, clean and dry the
spark plug. Then pull the
cranking rope several times
and reinstall the spark plug
• Spark plug connector not placed on.
• Place on the spark plug
connector
• Clean/replace spark plug
• Check ignition cable
Engine starts and is stalled
immediately
• Incorrect idle adjustment
• Contact customer service
Machine works with
interruptions
• Carburetor incorrectly adjusted
• Contact customer service
• Clean/replace spark plug
• Check spark plug connector
Overload indicator light glows
• Low voltage protection activated
Overload indicator light glows
• High temperature protection
activated
Overload indicator light glows
• Overload protection activated
Overload indicator light glows
• Short circuit protection activated
Should you in necessary repairs not able to properly to perform or you have
not the prescribed training for it always attract a workshop to fix the
problem.