EasyManua.ls Logo

FW Murphy VS2 - Specifications; VS2 and VS2 C; Vs2 Ex; Vs2 Exr

FW Murphy VS2
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 20 00-02-0185
2016-05-16 - 12 -
Specifications
VS2 and VS2C
Case: Environmental Protection: Ingress protected to IP54 (when mounted on a
horizontal surface with drain holes down)
VS2: Base Mount
VS2C: C-Clamp mount. Includes 45’ (13.7M), 2-conductor 16 AWG, 30 strands/0.25mm
strand diameter (1.5mm
2
) cable and five cable hold-down clamps
Contacts: SPDT double make leaf contacts, 3A @ 240 VAC, 10A @ 120 VAC; 10A @
32 VDC
Operating Temperature Range: -40
o
F to 185
o
F (-40
o
C to 85
o
C)
Range adjustment: 0-7 G’s; 0-100 Hz/0.10 in. displacement
VS2EX
Case: Explosion-proof aluminum alloy housing; meets IP54 specifications; Class I,
Division1, Groups C&D; UL and CSA listed*
VS2EX: Base mount
Snap switches: 2-SPDT snap-switches; 5A @ 480 VAC*; 2A resistive, 1A inductive, up
to 30 VDC
Operating Temperature Range: -40
o
F to 185
o
F (-40
o
C to 85
o
C)
Range adjustment: 0-7 G’s; 0-100 Hz/0.10 in. displacement
VS2EXR
Case: Same as VS2EX
Snap switch: 1-SPDT snap-switch and reset coil; 5A @480 VAC*; 2A resistive, 1A
inductive, up to 30 VDC
Remote reset:
Option Operating Current
-R15: 350 MA @ 115 VAC (momentary duty, not continuous)
-R24: 350 mA @ 24 VDC (momentary duty, not continuous)
Operating Temperature Range: -40
o
F to 185
o
F (-40
o
C to 85
o
C)
Range adjustment: 0-7 G’s; 0-100 Hz/0.10 in. displacement
VS2EXRB
Case: Explosion-proof aluminum alloy housing; constructed to meet Class I, Division 1,
Group B hazardous areas. No third-party certifications.
Snap-switch: 1-SPDT snap-switch with reset coil (option available for additional SPDT
switch); 5A @ 480 VAC; 2A resistive, 1 A inductive, up to 30 VDC.(-D option adds
another SPDT with the same rating)
Remote Reset:
Option Operating Current
-R15: 350 MA @ 115 VAC (momentary duty, not continuous)
-R24: 350 mA @ 24 VDC (momentary duty, not continuous)