F2.5 Enter Stand-By Mode on Power-Up Enable
d - Weight indication appears after display test.
E - Weight display will be disabled and all status indicators will be on until zero or tare
button is pressed.
F2.6 External Gross/Net Enable
d - Front panel gross/net switch active.
E - External gross/net input determines the mode of weight.
F2.7 Two Speed Feed Enable
d - Single speed outputs (six presets).
E - Two speed feed active (three presets).
F2.8 Sequential Feed Enable
d - Relays act in parallel fashion; both fast and slow relays energize below preset.
E - Relays act in sequential fashion; fast relay energizes, then slow relay energizes.
F2.9 Invert Relays Enable
d - RLY1 through RLY6 non -inverted output.
E - RLY1 through RLY6 inverted output. RLY7 (Fill Complete) and RLY8 (Zero
Interlock) remain as before.
F2.A Parallel Feed Enable
d - Relays operate in sequential order.
E - Independent action of relay output.