DIGITAL AUTOMATIC
BLOOD PRESSURE MONITOR
INSTRUCTION MANUAL
MODEL No.: MD2000/MD2010/MD2040/
MD2050/MD2001/MD2011/
MD2041/MD2051/MD2090
Version: 1
TABLE OF CONTENTS
INTRODUCTION...............................................................................1
COMPLIANCE...................................................................................1
SYMBOLS........................................................................................2
IMPORTANT NOTES.....................................................................2-4
DEVICE DESCRIPTION.................................................................5-6
BATTERY INSTALLATION.................................................................7
USE THE OPTIONAL AC ADAPTER .................................................8
SETTING DATE AND TIME................................................................9
BEFORE TAKING A MEASUREMENT................................................ 10
APPLYING ARM CUFF......................................................................10
PERFORMING BLOOD PRESSURE MEASUREMENT......................11
RECALL AVERAGE AND PREVIOUS MEASUREMENT DATA...........12
DELETE MEASUREMENT DATA......................................................12
PRESSURE BAR INDICATOR..........................................................13
WHO CLASSIFICATION INDICATOR...............................................13
ABOUT IRREGULAR HEARTBEAT ...................................................14
ABOUT BLOOD PRESSURE............................................................14
TROUBLESHOOTING......................................................................15
TECHNICAL SPECIFICATION.......................................................... 16
APPENDIX I...............................................................................17-18
APPENDIX II..............................................................................19-20
APPENDIX III.............................................................................21-22
APPENDIX IV.................................................................................. 23

Questions and Answers

  • S
    Samantha Flores DDSAug 12, 2025
    Why does ERROR code 1 (E1) appear on my G-Lab MD2000?
    • M
      Michael ClaytonAug 12, 2025
      ERROR code 1 (E1) appears because no pulse signal is detected, possibly due to incorrect cuff application. Reapply the cuff, ensuring it is fastened correctly and positioned at heart level.
  • K
    Kayla DayAug 15, 2025
    What to do if my G-Lab Blood Pressure Monitor displays ERROR code 6 (E6)?
    • D
      Donna BirdAug 15, 2025
      If your G-Lab Blood Pressure Monitor displays ERROR code 6 (E6), it indicates a low battery level. Replace all used batteries with new ones.
  • R
    robbinstamaraAug 19, 2025
    What does it mean when ERROR code 2 (E2) appears on my G-Lab MD2000 Blood Pressure Monitor?
    • J
      Jennifer McconnellAug 19, 2025
      ERROR code 2 (E2) appears because noise was detected, meaning there was movement of your arm or body during the measurement. Remain still and do not talk during the measurement.
  • C
    Carolyn HendersonAug 23, 2025
    What to do if my G-Lab MD2000 Blood Pressure Monitor displays nothing on the screen?
    • R
      ramirezalanAug 23, 2025
      If nothing appears on the display of your G-Lab Blood Pressure Monitor, even when turned on, it could be due to: * Drained batteries: Replace all used batteries with new ones. * Incorrect battery installation: Re-install the batteries, ensuring the polarities (“+” and “-“) match the markings in the battery compartment.
  • B
    Brett BartlettAug 27, 2025
    What does it mean when ERROR code 3 (E3) appears on my G-Lab MD2000?
    • C
      Christian JohnsonAug 27, 2025
      ERROR code 3 (E3) appears because no pressure is detected, which might be because the cuff is not fastened properly or is too loose. Reapply the cuff and make sure it is fastened correctly.
  • R
    Rhonda FrancisAug 30, 2025
    Why does my G-Lab MD2000 Blood Pressure Monitor keep re-inflating?
    • A
      aprilrivasAug 31, 2025
      The G-Lab Blood Pressure Monitor keeps re-inflating because of a system lockup. To resolve this, restart the device by removing the batteries, waiting one minute, and then re-installing them.
  • O
    oconnelldeborahSep 3, 2025
    What does it mean when ERROR code 4 (E4) appears on my G-Lab Blood Pressure Monitor?
    • J
      juliazimmermanSep 3, 2025
      ERROR code 4 (E4) appears because the device cannot measure blood pressure correctly. If the heartbeat is very weak or irregular, the device may not be able to measure the blood pressure. Reapply the cuff, fasten it correctly, sit comfortably, and remain still during the measurement.
  • M
    Mary KingSep 7, 2025
    What to do if my G-Lab MD2000 displays ERROR code 5 (E5)?
    • T
      Terrance ColemanSep 7, 2025
      If your G-Lab Blood Pressure Monitor displays ERROR code 5 (E5), it means the cuff is over inflated, and your blood pressure may be over 300 mmHg. It is recommended to consult your physician immediately.

Overview

The G.LAB® Digital Automatic Blood Pressure Monitor (Models: MD2000/MD2010/MD2040/MD2050/MD2001/MD2011/MD2041/MD2051/MD2090) is a non-invasive oscillometric device designed for quick and easy measurement of systolic and diastolic blood pressure, and pulse rate in adults. It is suitable for both home users and healthcare professionals.

Function Description:

The device utilizes an oscillometric method to measure blood pressure and pulse rate. An inflatable cuff is wrapped around the upper arm, and the device automatically inflates and deflates to take a measurement. The measurement results are displayed on an LCD screen and automatically saved to memory. Bluetooth-capable models can transmit measurement results to pre-approved mobile devices.

Important Technical Specifications:

  • Measurement Method: Non-invasive, Oscillometric method.
  • Measurement Range:
    • Systolic Blood Pressure: 50-250 mmHg
    • Diastolic Blood Pressure: 30-200 mmHg
    • Pulse Rate: 40-180 beats/minute
  • Accuracy:
    • Pressure: +/-3 mmHg
    • Pulse Rate: +/-5% of reading
  • Resolution:
    • Pressure: 1 mmHg
    • Pulse Rate: 1 beat / minute
  • Memory:
    • 480 records (120 x 4 users) for MD2000/MD2040/MD2001/MD2041 models.
    • 960 records (240 x 4 users) for MD2010/MD2050/MD2011/MD2051/MD2090 models.
  • Dimensions: Approximately 4.6" x 6.1" x 3" (117 x 154 x 75mm).
  • Cuff Size / Arm Circumference Range:
    • Standard: 9"-13" (22cm-32cm)
    • Large: 13"-17" (32cm-44cm)
    • Full Range: 9"-17" (22cm-44cm)
  • Operating Temperature: 41°F to 104°F (5°C to 40°C).
  • Operating Humidity: 15 to 93% RH.
  • Storage Temperature: -13°F to 158°F (-25°C to 70°C).
  • Storage Humidity: Up to 93% RH.
  • Operation, storage and transport atmospheric pressure: 700hPa to 1060hPa.
  • Power Source: 4 x 1.5V AA alkaline batteries (Optional AC Adapter 6VDC@600mA).
  • Classification: Application part Type BF, Class II equipment.
  • Compliance: Conforms to European Medical Device Directive 93/42/EEC, EN ISO 81060, EN 1060, EN 60601, ISO 81060-2, IEC 80601-2-30 standards.

Usage Features:

  • User-Friendly Interface: Easy-to-use for home users and healthcare professionals.
  • Automatic Data Storage: Automatically saves measurement data for review.
  • Multi-User Support: Stores data for up to 4 users (120 or 240 records per user depending on model).
  • Date and Time Setting: Allows users to set the current date and time for accurate record-keeping.
  • Average Data Recall: Displays the average of all previous measurement data, as well as AM/PM average data from the last 7 days.
  • Previous Measurement Data Recall: Allows viewing of individual past measurements, from most recent to oldest.
  • Pressure Bar Indicator: Illustrates cuff pressure condition during measurement.
  • WHO Classification Indicator: Provides a visual snapshot of blood pressure classification based on World Health Organization (WHO) standards, helping users understand their blood pressure values.
  • Irregular Heartbeat (IHB) Detection: Detects irregular heartbeats (variations of 25% from the average heartbeat) during measurement and displays an indicator if detected two or more times. Users are advised to consult a physician if this indicator frequently appears.
  • Battery Level Indicator: Displays current battery level and indicates when batteries need replacement.
  • Optional AC Adapter: Can be powered by an optional AC adapter (6VDC@600mA) in addition to batteries.
  • Safety Precautions:
    • Designed for adult use only; not for newborns, infants, children, toddlers, or persons unable to express intentions.
    • Avoid self-diagnosis or adjusting medication based on results; consult a physician.
    • Do not use on an arm with unhealed wounds or under medical treatment.
    • Avoid excessive measurement repetition to prevent discomfort or injury.
    • Ensure proper cuff size and placement for accurate readings.
    • Measurements should be taken in a quiet, comfortable indoor environment, at the same time each day for consistency.
    • Avoid eating, drinking alcohol or caffeinated beverages, smoking, exercising, or bathing for 30 minutes before measurement.
    • Rest for at least 5 minutes before each measurement.
    • Remain still and do not talk during measurement.
    • Position the cuff at heart level.
    • Sit comfortably with feet flat on the floor, not crossed, and back straight.
    • Do not use near flammable gases, in moving vehicles, or outside specified environments.
    • Keep small parts out of reach of children to prevent choking hazards.
    • Do not attempt to open, disassemble, repair, modify, or adjust the device.
    • Avoid strong knocks, extreme temperatures, high humidity, direct sunlight, dust, or chemicals.
    • Not water resistant; avoid water, rain, or sweat.
    • Do not fold the cuff tightly for long periods.
    • Remove arm jewelry before measurement.
    • Do not place heavy objects on the device during storage.

Maintenance Features:

  • Cleaning: Clean the device and cuff carefully with a dry, soft cloth or a cloth dampened with water. Avoid aggressive solvents.
  • Battery Replacement: Replace all used 1.5V AA alkaline batteries at the same time when the low battery indicator appears. Ensure correct polarity. Remove batteries if the device will not be used for a long period.
  • Regular Inspection: Generally recommended to have the monitor inspected every 2 years to ensure proper functioning and accuracy. Contact the dealer for maintenance.
  • Disposal: Dispose of used equipment, parts, batteries, and optional accessories according to applicable local regulations to prevent environmental pollution. The device and packaging should be disposed of correctly at the end of usage, following local ordinances or regulations.