Why does my GALILEO TP VACSOUND ECO D12 pump not start?
- MMatthew GibsonAug 13, 2025
If the GALILEO TP Industrial Equipment pump doesn't start or stops immediately, several issues could be the cause. First, the motor-pump coupling might be defective, so check the elastic joint and replace parts as needed. Second, the oil's viscosity might have increased; examine the oil and change it if necessary, also find out why it has deteriorated. Third, there could be excessive friction inside the pump; test the resistance to rotation by turning the joint by hand. If the rotors are blocked, disassemble the pump body and check the parts inside. Fourth, the electrical protections might not be set, so adjust them. Finally, if the oil is too viscous due to low room temperature, heat the oil to 20 °C or use an oil recommended for low temperatures.