Status LED
Status LED will only operate once a er the Energizer has been turned
on.
One ash Registra on sent to Energizer
Two ashes Registra on with Energizer con rmed
TROUBLESHOOTING
Problem Causes Solu on
Fence Monitor zone
does not appear
on the Energizer
Controller
Ba eries are at
Ba eries or ba ery
holder are installed
incorrectly
Fence Monitor
needs rese ng
There are 2 fence
monitors on the
same zone
The fence voltage
is less than 500V
The energizer
is incorrectly
connected to the
fence
Replace ba eries
Install ba eries
/ ba ery holder
correctly
Remove ba ery
holder for 5 minutes
to reset the Fence
Monitor
Give each fence zone
a unique number. See
p. 8.
Repair fence
Connect your earth
system to the earth
terminal (on the le ),
and the fence to the
fence terminal (on
the right)
Zone current
measures lower
than expected
Poor Fence
Monitor earth
Fence installa on
Ba eries are low
Use addi onal earth
stakes
Check all power to
zone runs through
the Fence Monitor
Replace ba eries
Error 21 is displayed
on a fence zone
Communica on
with Fence
Monitor has been
lost
Check the Fence
Monitor