9.7.5 Remove the switch box cover
NOTE
Unit 4kW 6kW 8kW 10kW 12kW 14kW 16kW 12kW 3-PH 14kW 3-PH 16kW 3-PH
overcurrent
18 18 19 19 30 30 30 14 14 14
Wiring size(mm
2
)
4.0 4.0 4.0 4.0 6.0 6.0 6.0 2.5 2.5 2.5
MCA : Max. Circuit Amps. (A)
TOCA : Total Over-current Amps. (A)
MFA : Max. Fuse Amps. (A)
MSC : Max. Starting Amps. (A)
RLA : In nominal cooling or heating test condition,the input Amps of compressor where MAX. Hz
can operate Rated Load Amps. (A)
KW : Rated Motor Output
FLA : Full Load Amps. (A)
Unit
8kW 10kW 12kW 14kW 16kW 12kW 3-PH 14kW 3-PH 16kW 3-PH
overcurrent
32 32 43 43 43 27 27 27
Wiring size(mm
2
)
8.0 8.0 10.0 10.0 10.0 4.0 4.0 4.0
1-phase 8-16kW and 3-phase 12-16kW standard with backup heater 9kW(3-phase)
Unit 4kW 6kW 8kW 10kW 12kW 14kW 16kW 12kW 3-PH 14kW 3-PH 16kW 3-PH
overcurrent
31 31 32 32 43 43 43 27 27 27
Wiring size(mm
2
)
6.0 6.0 8.0 8.0 10.0 10.0 10.0 4.0 4.0 4.0
1-phase 4-16kW and 3-phase 12-16kW standard with backup heater 3kW (1-phase)
1-phase 4-16kW standard and 3-phase 12-16kW standard
UNIT POWER SUPPLY
1-phase
LN
LN
LPS
FUSE
UNIT POWER SUPPLY
3-phase
LPS
FUSE
L1 NL2 L3
L3
N
L2L1
UNIT POWER SUPPLY
3-phase
LPS
FUSE
L1 NL2 L3
L3
N
L2L1
UNIT POWER SUPPLY
1-phase
LN
LPS
FUSE
The ground fault circuit interrupter must be 1 high-speed type of 30mA(<0.1s). Please use 3-core shielded wire.
The default of backup heater is option 3 (for 9kW backup heater). If 3kW or 6kW backup heater is needed, please
ask professional installer to change the Dip switch of S1 to option 1(for 3kW backup heater) or option 2(for 6kW backup
heater), refer to 10.1.1 FUNCTION SETTING.
Stated values are maximum values (see electrical data for exact values).
© All rights reserved - Galmet Sp. z o.o. Sp. K. Installation and operation manual - air-water heat pump Prima 129