Max Flow Rate | 3800 l/h |
---|---|
Max Suction Depth | 8 m |
Cable Length | 1.5 m |
Max Liquid Temperature | 35 °C |
Protection Class | IP X4 |
Voltage | 230 V |
Frequency | 50 Hz |
Connection Thread | 1" |
Inlet/Outlet Diameter | 1" |
Defines authorized use, transport limitations, and lists prohibited substances to avoid injury.
Warns about electromagnetic fields affecting medical implants and general electrical safety precautions.
Details minimum cross-section requirements for extension cables based on voltage and length.
Warns about suffocation hazards from small parts in polybags during installation.
Explains the principle of operation, water intake, pressurization, and cut-off pressure.
Guides on choosing a suitable, stable, dry, and ventilated installation site away from open water.
Details how to mount the pressure tank unit securely to a firm surface using screws.
Explains connecting the suction hose, emphasizing vacuum resistance and proper sealing.
Differentiates connection systems for flat gaskets and thread sealing tape.
Step-by-step guide on connecting the suction hose, ensuring airtightness and proper routing.
Guides on connecting the pressure hose, noting venting and proper angling.
Details connecting the pressure hose using the correct gasket and combi system options.
Instructions on how to start and stop the pump, including safety precautions.
Covers pump priming, handling no-flow issues, stopping, and general operational tips.
Instructions on how to clean the unit safely without using water jets or harsh chemicals.
Procedure for flushing the pump, especially after pumping chlorinated water.
Guides on checking and adjusting the air pressure in the reservoir to the correct level (approx. 1.0 bar).
Step-by-step instructions for cleaning the filter and check valve using a removal tool.
Detailed steps for safely decommissioning and storing the pressure tank unit, including draining.
Guides on releasing blocked impellers and a table of common problems, causes, and remedies.
Displays key performance specifications like flow rate, head, and noise levels for different models.