Fault Possible cause Remedy
No water feature operating Mains plug not plugged in. v Plug in mains plug.
Impeller unit is blocked. v Clean pump.
Electronic circuit breaker v Stand the pump in the
has been activated. water.
Reduced water feature Water feature insert is dirty. v Clean water feature insert.
and nozzle pipe.
Filter clogged. v Clean filter.
Pump shuts down after Water temperature too high. v Maximum water
a short time temperature is 35 °C.
A
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers
authorised by GARDENA.
7. Putting into Storage
The storage location must not be accessible to children.
1. Remove the underwater filter and fountain pump from the pond
before frost is expected and clean.
2. To avoid difficulties when starting up in the spring, we recom-
mend storing the pump in a frost-free location in a container
filled with water.
The mains plug must not be submerged.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
v Important: Make sure that the unit is disposed of via your
municipal recycling collection centre.
8. Accessories
GARDENA Illuminate water features and Art.-Nr. 7952 / 7954
Underwater lights the edges of the pond.
GARDENA Start water features and lighting Art.-Nr. 7874
radio control set from the terrace or your living
room.
Storage /
Overwintering:
Disposal:
(in accordance with
RL2002/96/ EC)