v If necessary, contact your local water
authority.
DANGER! This product makes an electromag-
netic field while it operates. This field may under
some conditions interfere with active or passive
medical implants. To decrease the risk of condi-
tions that can possibly injure or kill, we recom-
mend persons with medical implants to speak
with their physician and the medical implant
manufacturer before you operate the product.
DANGER! Small parts can be easily swallowed.
There is also a risk that the polybag can suffo-
cate toddlers. Keep toddlers away when you
assemble the product.
2. Function
The Electronic Pressure Pump is equipped with an electronic
control which automatically turns on the pump when the cut-in
pressure has fallen and automatically switches off when no
more water is extracted.
Low quantity programme: The integrated small amount programme allows for trouble-free
use of, for example, modern washing machines or drip irrigation
systems even with low water flow.
Error diagnosis system: The pump has an error diagnosis system which shows
different fault statuses and their remedies via the display
(see 8. Troubleshooting).
MENU
ß
II
ß
I
Display
Updated information on the operating conditions can be
shown depending on the display, and various settings can be
undertaken.
The display consists of a display area
ß
I
and a toolbar
ß
II
,
which states the respective functions of the 3 buttons below
e.g.:
Left button
Scroll menu upwards to
“Leakage warning”.
Centre button
Call up the “Turn on pressure” menu.
Right button
Scroll menu down to
“Troubleshooting”.
3. Installation
Positioning of Electronic
Pressure Pump:
The installation position must be firm and dry, and permit a secure
mounting for the Electronic Pressure Pump.
v Install the Electronic Pressure Pump at a safe distance
(min. 2 m) from the pumping medium.
The pump must be installed in a location with an air humidity of
< 80 % and sufficient ventilation in the area of the ventilation slots.
It must be at a distance of at least 5 cm from the walls. No dirt
contamination (e. g. sand or earth) may be sucked in through the
ventilation slots.
20
EN