Do you have a question about the Gardena 4000/4 LCD and is the answer not in the manual?
Max delivery capacity | 4000 l/h |
---|---|
Max self-priming suction | 8 m |
Cable length | 1.5 m |
Maximum liquid temperature | 35 °C |
Connection thread | 33.3 mm (G1) |
Power cable type | H07 RNF |
Protection class | IPX4 |
Voltage | 230 V |
Frequency | 50 Hz |
Inlet/Outlet | 33.3 mm (G1) |
Details the intended private use of GARDENA Electronic Pressure Pumps in homes and gardens.
Lists the types of liquids suitable for pumping by the GARDENA Electronic Pressure Pump.
Provides crucial information and warnings for safe and effective pump operation.
Critical warning about the risk of injury from electric shock when using the pump.
Guidance on selecting a safe and appropriate location for pump installation.
Recommendations for safe use of extension cables with the pressure pump.
Details electrical connection regulations specific to Austria and Switzerland.
Instructions to perform a visual inspection of the pump before starting operation.
Essential safety measures to follow during the pump's operation.
Explanation of the pump's electronic display, including symbols and indicators.
Details the different operating modes: priming, operation, and standby.
Guidelines on selecting the optimal and safe position for the pump.
Steps for permanently installing the pump into a domestic water system.
Instructions on how to correctly connect the suction hose to the pump's intake.
Guidance on connecting the delivery hose to the pump's output side.
Step-by-step instructions for powering on and initiating the pump's operation.
Description of the pump's status when idle and ready for use.
How to switch between different data displays on the pump's interface.
Explanation of the reset key's functions for quantity measurement and fault clearing.
Procedure to restart the pump after it has stopped due to an error.
Instructions for draining and storing the pump safely during cold seasons or long periods of inactivity.
Information regarding the environmentally compliant disposal of the pump unit.
Crucial safety warning to disconnect power before any maintenance.
Detailed steps for cleaning the pump's integrated filter unit.
Procedure for cleaning the pump's non-return valve assembly.
Instructions for removing and cleaning the valve body component of the pump.
Essential safety precaution to unplug the pump before attempting any troubleshooting.
Steps to diagnose and resolve issues when the pump display is blank.
Guidance on troubleshooting common pump operation errors like ERROR 02 and 03.
Diagnosing and rectifying situations where the pump switches off unexpectedly, indicated by ERROR 04.
Troubleshooting for errors indicated by a flashing Pump ON light (ERROR 06 to 09).
Steps to identify and fix leaks causing the pump to fault (ERROR 10).
Troubleshooting steps for reduced water flow on the delivery side of the pump.
Diagnosing issues causing low water intake and reduced performance.
How to use the manual mode for extended fault diagnosis without automatic shutdown.
Information on the GARDENA suction kit, including article numbers.
Details of available suction hoses and their corresponding fittings with article numbers.
Information on GARDENA suction filters, recommended for sandy water.
Details on the GARDENA pump preliminary filter for enhanced filtration.
Information about the GARDENA borehole suction hose for specific connection types.
Details on the product warranty period, conditions, and how to make a claim.