Edition 08.2019 · 610.44434.40.000 Original operating instructions · English
Operating Instructions G-BH1|G-BH9
2BH11|2BH12|2BH13|2BH14|2BH15|
2BH16|2BH18|2BH19|2BH923

Table of Contents

Questions and Answers

  • M
    matthew80Aug 19, 2025
    What to do if overcurrent protection triggered again after switching on Gardner Denver Elmo Rietschle 2BH1943 Water Pump?
    • R
      rochaaaronAug 19, 2025
      If the overcurrent protection is triggered after switching the motor on and the power consumption is too high on your Gardner Denver Water Pump, it could be due to several reasons. The motor might be overloaded, or the settings may deviate from the details on the rating plate, so reduce the settings. There could also be a short-circuit in the winding, so check the winding. Additionally, clogged filters, silencer elements, or connecting pipes/hoses can cause this issue, so clean them. Finally, the impeller could be grinding, or the rotor could be jammed, so open the pump, remove any foreign objects, and clean or replace the affected parts.
  • C
    Clayton Douglas MDAug 21, 2025
    What to do if Gardner Denver Elmo Rietschle 2BH1943 G-BH9 does not start up and makes noises?
    • A
      anitaholdenAug 21, 2025
      If your Gardner Denver Water Pump G-BH9 does not start up and makes noises, it could be due to a break in one of the power supply lines; in this case, correct the break in fuses, terminals or power supply lines. Alternatively, the impeller might be grinding, or the rotor is jammed, so open the G-BH1 | G-BH9, remove any foreign objects, and clean or replace parts. A faulty impeller or rolling bearing could also be the cause, so replace them if necessary.
  • I
    irogersAug 25, 2025
    What to do if Gardner Denver Elmo Rietschle 2BH1943 G-BH9 does not reach the required speed?
    • V
      Victoria HortonAug 25, 2025
      If your Gardner Denver Water Pump G-BH9 does not reach the required speed or shows no or too little differential pressure, check the direction of rotation. Also, leaks in the unit could be the problem, so seal the unit. If the density of conveyed media is fluctuating, take into account recalculation of pressure values and consult the manufacturer. Finally, a defective radial shaft seal can cause this, so replace the radial shaft seal.
  • C
    charleschristensenAug 26, 2025
    What to do if Gardner Denver Elmo Rietschle 2BH1943 drive control switches into fault after release?
    • J
      John FrostAug 26, 2025
      If the Gardner Denver Water Pump drive control switches into fault after release, it could be due to several reasons. The differential pressure might exceed the limits specified on the rating plate, so reduce the differential pressure. The impeller might be grinding, or the rotor is jammed, so open the G-BH1 | G-BH9, remove any foreign objects, and clean or replace parts. A faulty rolling bearing in the motor or compressor part could also be the cause, so replace the rolling bearing. Additionally, clogged filters, silencer elements, or connecting pipes/hoses can cause this issue, so clean them.
  • C
    Christine OconnorAug 28, 2025
    What to do if Gardner Denver Elmo Rietschle 2BH1943 Water Pump G-BH9 does not start up and does not make any noise?
    • K
      Kristen GreenAug 28, 2025
      If your Gardner Denver Water Pump G-BH9 does not start up and does not make any noise, it could be due to an interruption in the power supply of the G-BH1; correct the break in fuses, terminals or power supply lines. The drive control intermediate circuit voltage might be too low, so check the mains voltage and drive control. The drive control might be locked, so use the control block. An incorrect setpoint source or a target value of "0" for the drive control could also be the cause, so change the setpoint source or specify a target value.
  • K
    Kenneth GarciaAug 30, 2025
    Why does my Gardner Denver Elmo Rietschle 2BH1943 Water Pump G-BH9 turns unevenly?
    • M
      Mr. Tracy PerkinsAug 30, 2025
      If your Gardner Denver Water Pump G-BH9 turns unevenly, it could be due to a defective motor cable, so check the motor cable. Alternatively, there might be underexcitation or overexcitation of the drive control motor, so check the parameterisation. You should also check the motor data and, if necessary, identify the motor.
  • J
    Jessica JonesSep 1, 2025
    Why is my Gardner Denver Elmo Rietschle 2BH1943 G-BH9 leaking?
    • T
      Timothy LittleSep 1, 2025
      If your Gardner Denver Water Pump G-BH9 leaks, it may be due to loose screw connections. Check the tightening torques and tighten the screws.
  • W
    William AlexanderSep 3, 2025
    How to fix abnormal flow noises in Gardner Denver Water Pump?
    • B
      bjohnstonSep 3, 2025
      If you are experiencing abnormal flow noises with your Gardner Denver Water Pump, it may be because the flow rate is too high. Clean the pipes/hoses, and if necessary, use pipes/hoses with a larger cross section.
  • A
    Abigail Larsen MDSep 5, 2025
    How to fix change in the blade profile due to contamination in Gardner Denver Elmo Rietschle 2BH1943 Water Pump?
    • K
      Kevin CollierSep 5, 2025
      Clean the impeller of your Gardner Denver Water Pump and check for wear. Replace the impeller if necessary.
  • S
    Steve LarsenSep 8, 2025
    How to clean dirty or faulty silencer inserts in Gardner Denver Water Pump?
    • P
      Patricia RaySep 8, 2025
      Clean the silencer inserts of your Gardner Denver Water Pump, check for wear and replace as necessary.

Summary

Safety and responsibility

Explanation of warning signs

Explains the meaning of various warning signs and symbols used for safety.

Correct use of the equipment

Details the intended and correct application of the G-BH1 | G-BH9 compressor.

Unauthorised operation

Lists prohibited operations and conditions that can lead to damage or injury.

Working in a safety-conscious manner

Provides guidelines for safe working practices around the equipment.

Personnel qualifications and training

Specifies the required skills and training for various work tasks.

Personal protective equipment

Lists essential personal protective equipment (PPE) for safe operation.

Requirements of the operator

Defines operator responsibilities for safe and correct equipment usage.

Transportation and storage

Lifting and transporting

Details safe procedures and precautions for moving and transporting the unit.

Installation

Mounting conditions

Specifies environmental and structural requirements for installing the equipment.

Mounting

Instructions for physically mounting the G-BH1 | G-BH9 units.

Connecting pipelines and hoses

Details on how to connect gas inlet and outlet pipes and hoses safely.

Electric power connection

General installation regulations

Covers essential safety and electrical installation standards.

Controls

Describes requirements for control systems, including safety functions.

Connect the motor to the mains

Step-by-step guide for wiring the motor to the power supply.

Connect the drive control to the mains

Instructions for connecting the drive control unit to the main power.

Parameterising the drive control

Details on setting up and configuring the drive control parameters.

Operation

Switch on

Step-by-step guide to safely start the equipment.

Switch off

Instructions for safely shutting down the equipment.

Switch off in emergency

Procedures for immediate shutdown in emergency situations.

Troubleshooting

Faults and corrective measures

Identifies common faults and their corresponding solutions.