13-8-621 Page 36
Filter Element Life - The element should be replaced if visual inspection indicates an accumulation of
dirt, or a rupture, crack or pin holes in the pleated media. Inspection should be done by placing a bright
light inside the element.
WARNING
Do not oil this element. Never operate unit without element. Never use
elements that are damaged or ruptured. Never use elements that won’t seal.
Keep spare elements on hand to reduce downtime. Store elements in a
protected area free from damage, dirt and moisture. Handle filter parts with
care.