EasyManua.ls Logo

Gardner Denver L45 - North America Version L45 RS

Gardner Denver L45
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12. Annex
54
12.1.5 North America version L45RS
Technical Data 60Hz North America
L45RS
Maximum working pressure
psi g
190.0
Minimum working pressure
psi g
75.0
Ambient temperature min. / max.
°F
34...113
at min. speed
at max. speed
110 psi g
FAD
cfm
51.9
280.2
130 psi g
FAD
cfm
50.8
260.6
145 psi g
FAD
cfm
49.9
247.6
190 psi g
FAD
cfm
69.2
217.4
Approx discharge temperature of air above ambient
°F
13 (at max. power)
Free field noise level (ISO 2151) at 70% load / at 100% load
dB(A)
71 / 76
Nominal motor rating
hp (kW)
60 (45)
Nominal voltage (frequency)
460V[±10%] (60Hz)
Full load current max. at 460V
Amps
84
Standard drive motor detail
TEFC IP55, EPACT
Drive motor speed min./max.
rpm
800 … 4050
Fan motor rating
hp
2 (1.5) (IP-54)
Suggested cable size at 460V (cable type 167°F / Copper)
AWG 1
Suggested fuse rating at 460V (slow-blow fuse, class J)
Amps
110
Ventilating fan capacity
cfm
3072
Approx. cooling air temp above ambient (at max. power)
°F
52
Max. allowable pressure drop in duct at ambient 95°F / 113°F
Pa
120 / 80
Compressor oil capacity
gal ( l )
6 (23)
Compressed air delivery connection (male screwed thread)
1 1/2 -11 1/2 NPT
Weight
lbs / kg
2147 (974)
Package dimensions L x W x H
in / mm
67.8 x 36.2 x 65.3 (1722 x 920 x 1659)

Table of Contents