GB
NL
DE
FR
14
Cause Fault Remedy
Chainsaw does not operate No current supply Check current supply.
Defective outlet Try a different source of current,
change as necessary.
Extension cable damaged Check cable, replace if necessary.
Defective fuse Replace fuse
Chainsaw operates irregularly Mains cable damaged Take saw to a specialty workshop
External loose connection Take saw to a specialty workshop
Internal loose connection Take saw to a specialty workshop
Defective on/off switch Take saw to a specialty workshop
Saw chain dry No oil in the tank
Ventilation in the oil tank cap clogged Clean oil tank cap
Chain/guide rail hot No oil in the tank
Ventilation in the oil tank cap clogged Clean oil tank cap
Dull chain Re-sharpen or replace chain
Chainsaw jumps up, vibrates or
does not saw properly
Chain tension too loose Adjust chain tension
Dull chain Re-sharpen or replace chain
Chain worn out Replace chain
Saw teeth pulling in the wrong
direction
Re-mount saw chain with
teeth in the correct direction
14. EC Declaration of Conformity
We declare under our sole responsibility that the product Electric pole-mounted chain saw,to which this declaration
relates correspond to the relevant basic safety and health requirements of Directives 2006/42/EC(Machinery Directive),
2014/30/EU(EMV-Guideline)and2011/65/EU(ROHS-Guideline)incl.modifications.For the relevant implementation
of the safety and health requirements mentioned in the Directives,the following standards and/or technical
specification(S) have been respected:
EN 60335-1:2012+A11; EN 62233:2008; EN ISO11680-1:2011
EN 55014-1:2006+A1+A2;EN 55014-2:2015; EN 61000-3-2:2014; EN 61000-3-3:2013
Conformity assessment method to annexe V/Directive 2000/14/EC