Part # P153 (11/06) Page 7
3"
[76mm]
REAR CABLE
ENTRANCE
34"
[864mm]
16-14"
[413mm]
1-1/8"
[29mm]
18"
[457mm]
34-1/4"
[870mm]
20-1/4"
[514mm]
36"
[914mm]
DIMENSIONS AND SPECIFICATIONS, MODELS SERC, SER-680
Model Total Kw Load
TOTAL AMPS
208V/1Ph 208V/3 Ph 240V/1Ph 240V/3 Ph 400 V/3N 415V/3N
SERC, SER-680
wired independently
7 34 29 29 25 15 15
Installation Notes:
Clearances from combustible surfaces should be minimum 7” (178mm) from sides, 2” (51mm) from back
Note: Salamander can not be installed wired from the range base on a S684 in 208/1/60. Salamander must have
a separate circuit.
KW Ratings
Total kW loading is 7.0 kW
Model
Weight
Pounds KG
S/SUERC 164 76
S/SUER-680 190 86