32
Resolution
0.1 °C or 0.1 °F (°F resolution is derived from 0.1 °C)
Memory
max and min values
Alarm
upper limit (HI), lower limit (LO)
INDOOR RELATIVE HUMIDITY
Display range
10% to 99%
Accuracy
+/- 5%
Resolution
1%
Memory
max and min values
Alarm
upper limit (HI), lower limit (LO)
INTERNET TIME CONTROL
Time adjustment
from Internet, manual
Time display
HH:MM
Time display format
12-hour (AM / PM) or 24-hour
Date display format
DD/MM, MM/DD day name shortcut
Time zone
-12 to +12 hours
DST (daylight saving time)
on or off
INTEGRATED WIRELESS SENSOR GARNI 4INT
Dimensions
375 x 410 x 175 mm
Weight
702 g without batteries
Power supply
2 pcs AA batteries 1.5 V (lithium recommended)
Signal frequency
868 MHz
Maximum RF power
14 dBm (25 mW)
Signal range
up to 100 m in open space
Data transmission
Every 16 seconds
OUTDOOR TEMPERATURE
Temperature unit
°C, °F
Display range
-25 °C to +60 °C (-14 °F to 140 °F)
Accuracy
+/- 1 °C or 2 °F
Resolution
0.1 °C or 0.1 °F (°F resolution is derived from 0.1 °C)
Memory
max and min values
Alarm
upper limit (HI), lower (LO) limit of the current temperature
OUTDOOR RELATIVE HUMIDITY
Display range
10% to 99% (<1%: LO; >99%: HI)
Accuracy
+/- 5%
Resolution
1%
Memory
max and min values
Alarm
upper limit (HI), lower limit (LO) of the current humidity
RAIN GAUGE
Precipitation total units
mm, in
Precipitation total range
0-6000 mm (displays --- for out-of-range values)