SERIES 9800Q
PUMPS AND DISPENSERS
DIAGNOSTIC MANUAL
C36600
REV. 01/28/04
Copyright 2004 by Gasboy International LLC All rights reserved.
The information in this document is confidential and proprietary. No further disclosure shall be made without
permission of Gasboy International LLC. Gasboy International LLC believes that the information in this document is
accurate and reliable. However, we assume no responsibility for its use, nor for any infringements of patents or other
rights of third parties resulting from its use. We reserve the right to make changes at any time without notice.
GASBOY INTERNATIONAL LLC LANSDALE, PA

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Gasboy SERIES 9800Q and is the answer not in the manual?

Summary

Important Warnings and Safeguards

Electronic Head Assembly

CPU PCB Description

Describes the CPU PCB, its functions, and components.

LCD Display PCB

Contains the quantity display for the user and its interface.

RS-485 Interface PCB

Allows RS-485 communication with noise protection and diagnostic LEDs.

Pump Interface PCB

Sends pulser signals to external equipment and has diagnostic LEDs.

Power Supply PCB

Provides DC voltages, power failure warning, and battery backup.

Troubleshooting

9800 Q Dead: Displays Blank or Unable to Activate

Addresses issues where the unit is dead, displays are blank, or activation fails.

9800 Q Wont Activate in Standalone Mode

Troubleshoots activation failures in standalone mode when pump handle is thrown.

9800 Q Wont Activate in On-line Mode

Troubleshoots activation failures in on-line mode when pump handle is thrown.

9800 Q Not Communicating to GASBOY CFN System

Solves communication issues between the 9800Q and the GASBOY CFN system.

9800 Q Resets, No Fuel Dispense (Pump)

Addresses issues where the unit resets but fails to dispense fuel from the pump.

9800 Q Resets, No Fuel Dispense (Dispenser)

Addresses issues where the unit resets but fails to dispense fuel from the dispenser.

Leak Detector or Shear Valve Issues

Troubleshoots problems related to leak detectors and tripped shear valves.

Product Dispensed, No Quantity Displayed

Solves issues where product is dispensed but quantity is not shown on the display.

Incorrect Quantity Recording by Fuel Management System

Addresses discrepancies in quantity recorded by fuel management systems.

Replacement Instructions

Replacing the Platform Assembly

Step-by-step guide for replacing the platform assembly.

Replacing the CPU PCB

Instructions for removing and installing the CPU PCB.

Replacing the LCD Display PCB

Instructions for replacing the LCD Display PCB.

Replacing the Power Supply PCB

Instructions for replacing the Power Supply PCB.

Replacing the RS-485 or Pump I;F PCB

Instructions for replacing the RS-485 or Pump Interface PCB.

Gasboy SERIES 9800Q Specifications

General IconGeneral
BrandGasboy
ModelSERIES 9800Q
CategoryWater Pump
LanguageEnglish