www.gaslandchef.com
3330-A Marathon Ct Charleston, SC 29418
support@gaslandchef.com
1 (844) 538-7890
07
Leak Testing
WARNING
DO NOT SMOKE WHILE LEAK TESTING
Gas connections on the heater are leak tested at the factory prior to shipment.
Possible mishandling of the heater during the shipment might contribute to
product integrity as a whole. A complete gas leakage test must be performed
again at the installation site.
Please follow the procedure below for leakage test.
1. Make a soapy solution of one part liquid detergent and one part water. The
soapy solution can be applied with a spray bottle, brush or rag. Soap bubbles
will appear where the leak is present.
2. Make sure the control tap is in the <<OFF>> position (full disk =.) on the control
panel.
3. Turn on the gas supply and check for bubbles on the hoses and connections. If
the solution starts to bubble that means that a leak is present.
4. If a leak is present, turn OFF the gas supply immediately, tighten any leaking
fittings carefully and recheck to see if it still continues to leak.
5. Never leak test while smoking.
Installation
Important Safety Rules:
This heater is for OUTDOOR USE ONLY
1. This heater shall not be installed or used indoors, in buildings, garages or any
other enclosed area.
2. DO NOT place articles on or against this heater.
3. DO NOT use or store flammable materials near this heater.
4. Children and adults should be aware of the high surface temperature
hazard, and should keep a safe distance away to avoid clothes burning or
igniting.
5. Children should be carefully supervised when they are in the area of the heater.
6. NEVER hang anything including clothes or other flammable items on the
heater.