WARNING
• Improper installation, adjustment, alteration, service or maintenance can cause injury
or property damage.
• Read the instructions thoroughly before installing or servicing this equipment.
• THIS APPLIANCE MUST NOT BE INSTALLED OR USED INDOORS.
• NATURAL GAS APPLIANCE. TO BE INSTALLED ONLY BY AN AUTHORISED PERSON.
• THE AUTHORISED PERSON WILL PROVIDE A CERTIFICATE OF COMPLIANCE.
• An AGA approved high ow natural gas regulator must be installed in the pipeline and be set at 1kPa.
NOTE: BBQ MUST BE TESTED. AND PRESSURE MUST BE 1KPA WITH THE BURNER RUNNING
NATURAL GAS CONVERSION
TO BE INSTALLED ONLY ON OR IN A NON-
COMBUSTIBLE ENCLOSURE
Note: Recommended clearances must be maintained.
GAS PIPING
1. This appliance is only to be installed by an authorised
person.
2. Check with local and state plumbing and heating
codes regarding sizing of the gas lines.
3. All gas pipe connections must be sealed with a gas
pipe compound resistant to Natural Gas.
4. Installation of a drip leg if required in the gas supply
line must conform to AS5601.
5. When checking for gas leaks, do not use an open
ame. Use a soap and water solution and check for
bubbles indicating gas leakage.
6. Installation of 1/8” NPT plugged tapping, accessible
for test gauge connections, is required upstream of
the gas supply connection.
Warning
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Read
the instructions thoroughly before installing or servicing
this equipment.
SERVICING INSTRUCTIONS
Appliances should be serviced at least annually and
servicing must only be carried out by a Licensed Plumber
or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then replace
the Burner ensuring it is rmly secured.
Minimum Clearance for Ventilation:
Rear - 50mm Side - 50mm
NOTE TO THE INSTALLER:
Note: For natural gas conversion, you need to purchase
the special Natural Gas Valve with built-in Flame Failure
Device (FFD) from your supplier.
Similarly, to convert a natural gas version of the BBQ to
LPG, you need purchase the special LPG valve with built-
in FFD from your supplier for the conversion.
TEST OPERATION OF APPLIANCE
BEFORE LEAVING.
PROVIDE A CERTIFICATE OF COMPLIANCE.
Conversion ONLY to be done by an authorised person.
Overall Dimensions
Length Width Height
BQ2027
BQ2027BL
BQ2027NG
BQ2027BLNG
609mm 321mm 236mm