EasyManua.ls Logo

gc GRADIA PLUS - Additional Application and Repair; LABSIDE Procedures; CHAIRSIDE Procedures

gc GRADIA PLUS
166 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
II. ADDITIONAL APPLICATION AND REPAIR
A. LABSIDE
1. Roughen the resin surface using a carbide bur or sandblast (1.5 kg/cm
2
).
2. Immediately apply a silane coupling agent (e.g. CERAMIC PRIMER II) to the resin surface and dry.
3. Apply Enamel shades, etc. as required.
B. CHAIRSIDE
MASKING OF EXPOSED METAL SURFACES WHEN REPAIRING INDIRECT RESTORATIONS INTRAORALLY
1. As for PREPARATION of RESTORATION, refer to G-Premio BOND IFU-II.1.
Note: Use a rubber dam for isolation.
2. Apply GRADIA PLUS OPAQUE to the prepared metal surface only. The layer applied should have a thickness of
maximum 0.2 mm. Light-cure GRADIA PLUS OPAQUE for 20 seconds.
3. If the surface is still not sufficiently masked, apply a second layer of OPAQUE and light-cure.
Irradiation time
Curing unit Halogen / LED (700 mW/c) & High power
LED (more than 1200 mW/cm²)
OPAQUE 20 seconds
4. Repair the restoration by applying a chairside composite material (e.g. G-ænial & Essentia) in layers. Light-cure each
layer according to the manufacturer’s instructions of the respective product
5. Finish and polish using standard techniques.
Irradiation time and curing unit
Curing unit LABOLIGHT DUO STEPLIGHT SL-I LABOLIGHT LV-III,II
Step-mode** Full-mode Pre-Cure** Final cure
OPAQUE - 1 min. - 1 min.
PASTE HB, PASTE LB,
GUM SHADES LB,
GUM SHADES HB
10 sec.* 3 min. 10 sec.* 3 min.
LUSTRE PAINT *** 10 sec.* 90 sec. 10 sec.* 5 min.
* For one surface of a single crown.
** Distance from light source : 3cm.
*** Thickness: 0.1mm or less.
EN