GFKĆ1029B Chapter 2 Installing and Starting the Software
        

The Beame & WhitesideĆConnect TCP product comes with thorough installation instrucĆ
tions in the Installation Guide for Beame & Whiteside Software, GFKĆ1273. Some specific
areas of the process are worth noting.
1. The Installation Guide (GFKĆ1273) contains information for two Beame & Whiteside
products: BWĆTCP and BWĆNFS. Only BWĆTCP is distributed with this product.
2. Be sure that the system requirements given in GFKĆ1273 are met. This will assure
that the process is not terminated before completion.
3. Fill out the Preliminary Worksheet in GFKĆ1273. A modified version of this
worksheet also appears in Appendix A of this manual. Having this information
available will make the installation process easier.
4. When running the install program, you will be given the option of setting the Buffer
Space used by the driver. The default value is 26000. Changing this to 10000 will free
up more conventional memory, which is needed for Logicmaster 90 software to run.
When you have installed the Beame & Whiteside software in your PC, you must check
your system to determine if the required amount of Free Conventional Memory is availĆ
able. Instructions on how to read this value are given in Computer Requirements for
Running the Software" on page 2Ć2. If the requirements are not met, refer to the docuĆ
mentation for your memory manager software to find examples on how to load device
drivers into high memory. (For example, MSĆDOS EMM386 memory manager uses the
command DEVICEHIGH in place of the standard DEVICE statement to load a driver
into high memory.) We recommend loading both Beame & Whiteside drivers
(ETHDEV.SYS and TCPIP.SYS) into high memory.
Once memory requirements are met, various utilities provided by the BWĆConnect
product should be used to test the validity of the TCP/IP configuration. In particular, the
ping" utility should be used to verify that the PLCs to which you desire communication
are reachable. Further information on the use of ping" can be found in the TCP/IP EtherĆ
net Communications for the Series 90Ć70 PLC User's Manual (GFKĆ1004) and in TCP/IP EtherĆ
net Communications for the Series 90Ć30 PLC Station Manager's Manual (GFKĆ1186).
BWĆConnect is a trademark of Beame & Whiteside Software, Inc.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Fanuc Logicmaster 90-30 and is the answer not in the manual?

GE Fanuc Logicmaster 90-30 Specifications

General IconGeneral
Series90-30
Communication PortsRS-232, RS-485, Ethernet (optional)
TypePLC
Programming LanguageLadder Logic
CPU TypeIntel 80186
Power Supply120/240 VAC or 24 VDC
Operating Temperature0°C to 60°C
Relative Humidity5 to 95% non-condensing
Programming SoftwareLogicmaster 90-30