1
,QVWDOODWLRQ,QVWUXFWLRQV
ZZZ*(,QWHUORJL[FRP
*(,QWHUORJL[
'
Product
Summary
The ATP1000 lets you control all programming and operation of compatible security systems
(see the “Specifications” section).
The large 2-line, 16-character display provides easy to read messages to indicate the current sta-
tus of the system. The touchpad includes police, fire, and auxiliary panic buttons that can be acti-
vated anytime. A built-in speaker provides alarm, status, and button-press sounds. A swing-
down door reveals a label with basic system operating commands. The door can be removed by
simply opening it past its stop point. The door can also be reattached later if desired.
Tools and Equipment Needed
4-conductor, 22- or 18-gauge wire
Screwdriver
#6 screws and anchors (included)
Panhead screws for gang box installation
Saw or utility knife for cutting wallboard
Installation Guidelines
Mount the touchpad in an environmentally controlled area (32°F to 120°F/0°C to 49°C).
When mounting the touchpad, allow at least 3 inches below it for the swing-down cover.
Do not exceed the maximum available power. See the panel installation instructions for max-
imum available power.
Table 1 describes the power used by the touchpad.
Table 2 describes the maximum wire lengths allowed between the touchpad and the panel.
Table 1: Touchpad Power Usage
Current (mA) Conditions
110 Maximum alarm current with the
buzzer sounding and the touchpad
illuminated from a button press
60 Typical operation
12 Power saving mode (no panel AC
power)
Table 2: Maximum Touchpad Wire Lengths
Wire Gauge
(Unshielded or
Shielded)
Max. Touchpad Wire Length
Between Touchpad and Panel
18 750 feet
22 300 feet
'RFXPHQW1XPEHU5HY$
2FWREHU
$737RXFKSDG'LVSOD\
0RGHO1R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix ATP1000 and is the answer not in the manual?

GE Interlogix ATP1000 Specifications

Power Requirements IconPower Requirements
power requirement12 VDC nominal
Operating Environment IconOperating Environment
temperature range32°F (0°C) to 120°F (49°C)
maximum humidity95% relative, non-condensing
Weight and Dimensions IconWeight and Dimensions