Product
Summary
The ATP1000 lets you control all programming and operation of compatible security systems
(see the “Specifications” section).
The large 2-line, 16-character display provides easy to read messages to indicate the current sta-
tus of the system. The touchpad includes police, fire, and auxiliary panic buttons that can be acti-
vated anytime. A built-in speaker provides alarm, status, and button-press sounds. A swing-
down door reveals a label with basic system operating commands. The door can be removed by
simply opening it past its stop point. The door can also be reattached later if desired.
Tools and Equipment Needed
4-conductor, 22- or 18-gauge wire
Screwdriver
#6 screws and anchors (included)
Panhead screws for gang box installation
Saw or utility knife for cutting wallboard
Installation Guidelines
Mount the touchpad in an environmentally controlled area (32°F to 120°F/0°C to 49°C).
When mounting the touchpad, allow at least 3 inches below it for the swing-down cover.
Do not exceed the maximum available power. See the panel installation instructions for max-
imum available power.
Table 1 describes the power used by the touchpad.
Table 2 describes the maximum wire lengths allowed between the touchpad and the panel.
Table 1: Touchpad Power Usage
Current (mA) Conditions
110 Maximum alarm current with the
buzzer sounding and the touchpad
illuminated from a button press
60 Typical operation
12 Power saving mode (no panel AC
power)
Table 2: Maximum Touchpad Wire Lengths
Wire Gauge
(Unshielded or
Shielded)
Max. Touchpad Wire Length
Between Touchpad and Panel
18 750 feet
22 300 feet
'RFXPHQW1XPEHU5HY$
2FWREHU
$737RXFKSDG'LVSOD\
0RGHO1R

Questions and Answers

  • G
    gmoyerAug 1, 2025
    What to do if my GE Interlogix ATP1000 displays a flashing * and doesn't respond?
    • A
      Andrew RothAug 1, 2025
      If the GE Interlogix Touch Panel display shows a flashing asterisk and doesn't respond to commands, check the bus wiring connections (green and white wires) at both the touchpad and panel terminals. Also, ensure the touchpad unit number is different from all other bus devices. If needed, change the touchpad unit number, especially if you are using Concord panels with software versions 1.0-1.6.
  • T
    Todd TorresAug 11, 2025
    How to troubleshoot GE Interlogix Touch Panel that doesn't power up?
    • J
      Justin SmithAug 11, 2025
      If your GE Interlogix Touch Panel doesn’t power up, with no display or beeps when buttons are pressed, check the wiring connections at both the touchpad and panel terminals. Also, ensure the panel battery is correctly connected and the panel transformer is plugged in. Verify that the panel transformer is plugged into an outlet that is not controlled by a switch; if it is, relocate it to an unswitched outlet.
  • U
    uwalkerAug 21, 2025
    Why is my GE Interlogix ATP1000 display blank but beeping?
    • P
      Penny WatkinsAug 22, 2025
      If the GE Interlogix Touch Panel display appears blank but you hear beeps when pressing buttons, check the touchpad display contrast setting. It might be set to 0, resulting in no display.

Summary

Product Summary

Tools and Equipment Needed

Installation

Installation Guidelines

Guidelines for mounting the touchpad in an environmentally controlled area and power considerations.

Installing the Mounting Plate

Steps to separate the touchpad and mount the plate on the wall for installation.

Wiring the Touchpad to the Panel

Instructions for connecting the touchpad wires to the security system panel.

Attaching the Touchpad to the Mounting Plate

Steps to connect the touchpad to its mounting plate after wiring is complete.

Power Up and Bus Communication

Connecting the Touchpad for System Programming Only

Testing

Adjusting Display Brightness and Contrast

Troubleshooting

Changing the Touchpad Unit Number

Guidelines for changing touchpad unit numbers to avoid communication conflicts.

Specifications

Notices

GE Interlogix ATP1000 Specifications

Power Requirements IconPower Requirements
power requirement12 VDC nominal
Operating Environment IconOperating Environment
temperature range32°F (0°C) to 120°F (49°C)
maximum humidity95% relative, non-condensing
Weight and Dimensions IconWeight and Dimensions
dimensions5.0” x 4.50” x 0.75” (L x W x D)