3.2 MON OUT (BNC)
The monitor output BNC connector can accept the BNC connector of a local monitor or of a
monitor used to test camera setup.
3.3 E
XTERNAL
S
YNC
PHASE A
DJUSTMENT
B
UTTONS
CAUTION:
The phase adjustment must be made by a qualified service person or installer.
The vertical phase of the camera video signal can be synchronised to the phase of the AC power
line by using a dual-trace oscilloscope to observe the video output signal (V-rate) of the camera
and by adjusting the line-lock phase control buttons to line up the phases of both signals. In line-
lock mode, this synchronisation is automatic.