Performance Data Sheet
SmartWater Filtration Sgstem-GE®MWF Cartridge
This sgstem has been tested and certified in filter model GE HWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below, The
concentration of the indicated substances in water entering the sgstem was reduced to a concentration less than or equal to the permissible limit for water
leaving the sgstem, as specified in NSF/ANSI Standards 42 and 53,* (Safetg factors built in for unmetered usage)
Standard No. 42: Aesthetic effects
Substance NSFSpecifiedChal!enge Average % Average Product I Max Permissible Product_ NSF Reduction
Reduction Averagelnfluent Concentrat on Reduct on WaterConcentrat on WaterConcentrat on URequ rements
2.0 mg/L
J
NSFTest
Report
.I-00077703
J-00077704
Standard No. 53: Health effects
Substance
Reduction
NSFSpecified Challeng e Average %
Concentration Reduction
MinimumSO,O00c_ 99. %
1ffto I(_ fibers/L; fibers
reater than 10
/L _+10%
IL_+10%
0.08 mg/L _+10%
/L _+10%
IL _+10%
IL _+10%
IL_+ 10%
0.006 mg/L _+10%
/L _+10%
_L_+10%
0.015 mg/L_+ 10%
/L_+ 10%
0.210 rag/L_+ 10%0.218 mg/L
*Basedon the use of Cryptosporidium parvum oocysts
Capacity 300gallons (1,135liters). Contaminant reduction determined by NSF
Application Guidelines/Water Supply Parameters
Service Flow
Water Su_
>99%
1
94.5%
96,7%
98.7%
95.6°/o
99.3°(o ......................................
99.3%
99% ............................................
93,2 °/o.......................................
93,2%
99,7O(o
96,6%
93,2% .......................................
99,5%
testing,
Average Product
Water Concentration
_st/L
<1 MF/L
O.OO1mg/L
0,000__
9:999R7m_LL...................................................
Max Permissible Product
Water Concentration
NiA
NiA
O.04mg/L
o.oQ?m_&...................................................................................
NSF Reduction
Requirements
_>99.95%
_>99%
NiA
NiA
NiA
N/A
NiA
NiA
............................................................................NIA
NSFTest
Report
J-00077721
J-00077707
J-00077708
J-00077717
J-00077718
J-00082185
J-00077722
J-00077723
J-00077726
9:999!mg&............................................................................................................................................................N/A J-00077727
NiA J-00077728
0,005 m /L 0,075 m /L N_A...............................................................................................
O.O005mg/L O.OOSmg/L NiA J-00082184
£:££] _9_£ ......................................................................£:££_ _9_£ ....................................................................................NIA J-00077730
O,O009mg/L O.07mg/L NiA J-00077705
Water Pressure
Water Temperature
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Operating Specifications
Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
Temperature: ]5-100°F (0.6-58°C)
Flow rate: 0.Sgpm (1.9 Ipm)
General Installation/Operation/Maintenance Requirements
Flushnew cartridgeatfullflow for14/2 gallons(aboutthreeminutes)to purge
trappedoh.
Replacecartridgewhen flow becomestooslow.
Protectfrom freezing by removingfiltercartridge whentemperatures are
expectedto drop below ]]°F ('I°C),Donot install sgstems in areaswhere
ambienttemperatures mag go above 100°For below40°F,Donot install
on a hot water supplg.
Special Notices
Installation instructions are included with the product when shipped.
This drinking water sgstem must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
Do not use with water that is microbiologicallg unsafe or of unknown qualitg
without adequate disinfection before or after the sgstem. Sgstems certified for
cgst reduction mag be used on disinfected water that mag contain filterable cgsts.
The contaminants or other substances removed or reduced bg this water
treatment sgstem are not necessarilg in gour wateL
Check for compliance with the applicable state and local laws and regulations.
Note that while the testing was performed under standard laboratorg conditions,
actual performance mag varg. Sgstems must be installed and operated in
accordance with manufacturer's recommended procedures and guidelines.
Installation and use MUSTcomplg with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. If gour water pressure exceeds 80 psi
(552kPa),gou should install a pressure-limiting valve. Contact a plumbing
professional if gou are uncertain how to check gour water pressure.
Do not install where water hammer conditions mag occur. If water hammer
conditions exist gou must install a water hammer arrestei. Contact a plumbing
professional if gou are uncertain how to check for this condition.
Where a backflow prevention device is installed on a water system, a device for
controlling pressure due to thermal expansion must be installed.
Tested and Certified bg NSF International against ANSI/NSF Standards 42 and 53 in model GE MWF for the reduction of:
Standard No. 42: Aesthetic Effects
Chemical
- Chlorine Taste and Odor
Mechanical Filtration
- Particulate Reduction, Class I
GE
Appliances
Appliance Park
Louisville, KY40225
gea pplia ncepa rts.com
Standard No. 53: Health Effects
Chemical Reduction
- Atrazine Reduction
- Endrin Reduction
- Benzene and Carbofuran Reduction
- 1,8 Dichlorobenzene and
2,4-D Reduction
- Leadand Lindane Reduction
- Mercurgand Toxaphene Reduction
MechanicalFiltration
- Cgstand AsbestosReduction
REPLACEMENT
ELEMENT
© 2010 GE Compang PC61278B